Scanning vibrating reference electrode technique: a calibration study to evaluate the optimum operating parameters for maximum signal detection of point source activity

被引:41
作者
Akid, R
Garma, M
机构
[1] Sheffield Hallam Univ, Inst Mat Res, Ctr Corros Technol, Sheffield S1 1WB, S Yorkshire, England
[2] Univ Ramon Llul, IQS, Barcelona 08017, Spain
关键词
scanning electrochemical probe; localised corrosion; SVET; calibration;
D O I
10.1016/j.electacta.2004.01.069
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The application of scanning electrochemical techniques to evaluate and spatially resolve corrosion activity has progressively increased over the last 20 years. Electrochemical scanning techniques are based principally upon the assumption that localised corrosion, where the anodic and cathodic processes take place at separate sites, can be represented as point sources. The electric field generated by sites of localised corrosion consists of equipotential lines which can be measured and graphically represented as a contour map. Many modem day systems use either a static or vibrating reference or quasi-reference electrode, to measure the electric field, more specifically the field normal (perpendicular) to the surface. The latter of these systems, namely the vibrating electrode, allows for improved resolution and a lower minimum detectable signal. The following paper presented here discusses a study conducted to evaluate the influence of the operating parameters on the resolution and minimum detectable signal measurable using a scanning vibrating electrode system. Measurement of the electric field generated at a point source, namely, a gold point in space (PIS) electrode, is used to evaluate the effect of parameters such as probe scan speed, vibration amplitude and probe-sample distance on the peak output potential and the resolution, defined here as the ratio of the peak potential to the full width at half-maximum peak potential (FWHM). (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2871 / 2879
页数:9
相关论文
共 11 条
[1]   APPARATUS FOR THE EXAMINATION OF LOCALIZED CORROSION BEHAVIOR [J].
GAINER, LJ ;
WALLWORK, GR .
CORROSION, 1979, 35 (02) :61-67
[2]   COMMENTS ON MICROELECTRODES [J].
GESTELAND, RC ;
HOWLAND, B ;
LETTVIN, JY ;
PITTS, WH .
PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1959, 47 (11) :1856-1862
[3]  
Isaacs H. S., 1974, LOCALIZED CORROSION, V3, P158
[4]   SURFACE PREPARATION AND PIT PROPAGATION IN STAINLESS-STEELS [J].
ISAACS, HS ;
KISSEL, G .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1972, 119 (12) :1628-&
[5]   THE EFFECT OF HEIGHT ON THE CURRENT DISTRIBUTION MEASURED WITH A VIBRATING ELECTRODE PROBE [J].
ISAACS, HS .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (03) :722-728
[6]  
ISAACS HS, 1981, ASTM STP, V727, P3
[7]   ULTRASENSITIVE VIBRATING PROBE FOR MEASURING STEADY EXTRACELLULAR CURRENTS [J].
JAFFE, LF ;
NUCCITELLI, R .
JOURNAL OF CELL BIOLOGY, 1974, 63 (02) :614-628
[8]   Investigating changes in corrosion mechanism induced by laser welding galvanised steel specimens using scanning vibrating electrode technique [J].
McMurray, HN ;
Searle, JR ;
Wilson, BP ;
Worsley, DA .
BRITISH CORROSION JOURNAL, 2002, 37 (03) :225-230
[9]  
PHILIPPE X, 2000, P 7 INT S EL METH CO
[10]   MICROCOMPUTER CONTROLLED SCANNING REFERENCE ELECTRODE TECHNIQUE APPARATUS DEVELOPED TO STUDY PITTING CORROSION OF GAS-TURBINE DISK MATERIALS [J].
SARGEANT, DA ;
HAINSE, JGC ;
BATES, S .
MATERIALS SCIENCE AND TECHNOLOGY, 1989, 5 (05) :487-491