Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy

被引:122
作者
Lu, Weiguo
Olivera, Gustavo H.
Chen, Quan
Ruchala, Kenneth J.
Haimerl, Jason
Meeks, Sanford L.
Langen, Katja M.
Kupelian, Patrick A.
机构
[1] TomoTherapy Inc, Madison, WI 53717 USA
[2] Univ Wisconsin, Madison, WI USA
[3] MD Anderson Canc Ctr, Orlando, FL USA
关键词
D O I
10.1088/0031-9155/51/17/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The incorporation of daily images into the radiotherapy process leads to adaptive radiation therapy ( ART), in which the treatment is evaluated periodically and the plan is adaptively modified for the remaining course of radiotherapy. Deformable registration between the planning image and the daily images is a key component of ART. In this paper, we report our researches on deformable registration between the planning kVCT and the daily MVCT image sets. The method is based on a fast intensity-based free-form deformable registration technique. Considering the noise and contrast resolution differences between the kVCT and the MVCT, an `edge-preserving smoothing' is applied to the MVCT image prior to the deformable registration process. We retrospectively studied daily MVCT images from commercial TomoTherapy machines from different clinical centers. The data set includes five head-neck cases, one pelvis case, two lung cases and one prostate case. Each case has one kVCT image and 20-40 MVCT images. We registered the MVCT images with their corresponding kVCT image. The similarity measures and visual inspections of contour matches by physicians validated this technique. The applications of deformable registration in ART, including `deformable dose accumulation', `automatic re-contouring' and `tumour growth/regression evaluation' throughout the course of radiotherapy are also studied.
引用
收藏
页码:4357 / 4374
页数:18
相关论文
共 58 条
[1]   MULTIRESOLUTION ELASTIC MATCHING [J].
BAJCSY, R ;
KOVACIC, S .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1989, 46 (01) :1-21
[2]   Robust anisotropic diffusion [J].
Black, MJ ;
Sapiro, G ;
Marimont, DH ;
Heeger, D .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1998, 7 (03) :421-432
[3]   RADIOTHERAPEUTIC COMPUTED-TOMOGRAPHY WITH SCANNED PHOTON BEAMS [J].
BRAHME, A ;
LIND, B ;
NAFSTADIUS, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (01) :95-101
[4]   Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[5]   Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines [J].
Coselmon, MM ;
Balter, JM ;
McShan, DL ;
Kessler, ML .
MEDICAL PHYSICS, 2004, 31 (11) :2942-2948
[6]   Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer [J].
Ford, EC ;
Chang, J ;
Mueller, K ;
Sidhu, K ;
Todor, D ;
Mageras, G ;
Yorke, E ;
Ling, CC ;
Amols, H .
MEDICAL PHYSICS, 2002, 29 (12) :2913-2924
[7]   The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes [J].
Forrest, LJ ;
Mackie, TR ;
Ruchala, K ;
Turek, M ;
Kapatoes, J ;
Jaradat, H ;
Hui, S ;
Balog, J ;
Vail, DM ;
Mehta, MP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05) :1639-1644
[8]  
GEE JC, 2003, 2 INT WORKSH WBIR 20
[9]   A performance comparison of flat-panel imager-based MV and kV cone-beam CT [J].
Groh, BA ;
Siewerdsen, JH ;
Drake, DG ;
Wong, JW ;
Jaffray, DA .
MEDICAL PHYSICS, 2002, 29 (06) :967-975
[10]   Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART) [J].
Guan, HQ ;
Zhu, YP .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2925-2937