Qualitative and quantitative determination of biologically active low-molecular-mass thiols in human blood by reversed-phase high-performance liquid chromatography with photometry and fluorescence detection

被引:127
作者
Ivanov, AR
Nazimov, IV
Baratova, LA
机构
[1] Russian Acad Sci, Shemyakin & Ovchinnikov Inst Bioorgan Chem, Moscow 117871, Russia
[2] MGU, Belozersky Inst Phys & Chem Biol, Moscow 119899, Russia
关键词
thiols; aminothiols; homocysteine; monobromobimane; cysteine; glutathione;
D O I
10.1016/S0021-9673(99)00947-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The reversed-phase high-performance liquid chromatographic method employing photometry and fluorescence detection is described for the precise reproducible simultaneous measurement of total homocysteine (tHcy), cysteine (Cys), and glutathione (GSH) in human blood. Sample preparation involves conversion of disulfides to free thiols with triphenylphosphine, precipitation of proteins with trichloroacetic acid, conjugation of the thiols with monobromobimane (mBrB). The aminothiol assay is optimized by reduction and derivatization step conditions (pH, temperature and time of reactions) to obtain reliable quantitative results within the concentration range corresponding to normal and pathological levels of these thiols in human blood. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:433 / 442
页数:10
相关论文
共 25 条
[1]  
ANDERSSON A, 1993, CLIN CHEM, V39, P1590
[2]   DETERMINATION OF FREE AND TOTAL HOMOCYSTEINE IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
ARAKI, A ;
SAKO, Y .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 422 :43-52
[3]   HIGHER TOTAL PLASMA HOMOCYSTEINE IN VITAMIN-B12 DEFICIENCY THAN IN HETEROZYGOSITY FOR HOMOCYSTINURIA DUE TO CYSTATHIONINE BETA-SYNTHASE DEFICIENCY [J].
BRATTSTROM, L ;
ISRAELSSON, B ;
LINDGARDE, F ;
HULTBERG, B .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1988, 37 (02) :175-178
[4]   SENSITIVE MEASUREMENT OF GLUTATHIONE USING ISOCRATIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
BURTON, NK ;
AHERNE, GW .
JOURNAL OF CHROMATOGRAPHY, 1986, 382 :253-257
[5]  
Daskalakis I, 1996, BIOMED CHROMATOGR, V10, P205, DOI 10.1002/(SICI)1099-0801(199609)10:5<205::AID-BMC589>3.3.CO
[6]  
2-G
[7]   ANALYSIS OF HEPATIC REDUCED GLUTATHIONE, CYSTEINE AND HOMOCYSTEINE BY CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
DEMASTER, EG ;
SHIROTA, FN ;
REDFERN, B ;
GOON, DJW ;
NAGASAWA, HT .
JOURNAL OF CHROMATOGRAPHY, 1984, 308 (JUN) :83-91
[8]  
FISKERSTRAND T, 1993, CLIN CHEM, V39, P263
[9]   DETERMINATION OF PLASMA HOMOCYSTEINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
JACOBSEN, DW ;
GATAUTIS, VJ ;
GREEN, R .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (01) :208-214
[10]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR REDUCED AND OXIDIZED GLUTATHIONE IN BIOLOGICAL SAMPLES [J].
JAYATILLEKE, E ;
SHAW, S .
ANALYTICAL BIOCHEMISTRY, 1993, 214 (02) :452-457