Simultaneous determination of ultra-trace lead and cadmium at a hydroxyapatite-modified carbon ionic liquid electrode by square-wave stripping voltammetry

被引:84
作者
Li, Yonghong [1 ]
Liu, Xiaoying [1 ]
Zeng, Xiandong [1 ]
Liu, Yong [1 ]
Liu, Xiaotao [1 ]
Wei, Wanzhi [1 ]
Luo, Shenglian [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2009年 / 139卷 / 02期
基金
美国国家科学基金会;
关键词
Carbon ionic liquid electrode; Hydroxyapatite; Square-wave anodic stripping voltammetry; Heavy metal; PASTE ELECTRODE; ELECTROCATALYTIC OXIDATION; DIRECT ELECTROCHEMISTRY; SILVER ELECTRODE; HEAVY-METALS; MERCURY; REMOVAL; COPPER; PALLADIUM; ZINC;
D O I
10.1016/j.snb.2009.03.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a hydroxyapatite-modified carbon ionic liquid electrode (HAP-CILE) for the simultaneous determination of lead and cadmium was developed. The hydroxyapatite which combines with ionic liquid plays an important role in remarkable responses of metals. Trace analysis of the selected heavy metals was performed by Square-wave anodic stripping voltammetry (SWASV). The oxidation of two metals yielded well-defined, separated square-wave peak currents. The peak currents at about -0.34V for Pb2+ and -0.88V for Cd2+ were measured. The affecting factors containing supporting electrolyte, pH of solution, accumulation time, deposition potential, amount of hydroxyapatite and possible interferences were investigated. The sensor exhibited linear behavior in the range of 1 x 10(-9) mol L-1 to 1 x 10(-7) mol L-1 for lead and cadmium (correlation coefficients: 0.995 and 0.997, respectively) with detection limits of 2 x 10(-10) mol L-1 for lead and 5 x 10(-10) mol L-1 for cadmium. The results indicate that the sensor is sensitive and effective for the simultaneous determination of lead and cadmium. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:604 / 610
页数:7
相关论文
共 48 条
[1]   Lead determination by anodic stripping voltammetry using a p-phenylenediamine modified carbon paste electrode [J].
Adraoui, I ;
El Rhazi, M ;
Amine, A ;
Idrissi, L ;
Curulli, A ;
Palleschi, G .
ELECTROANALYSIS, 2005, 17 (08) :685-693
[2]   Determination of lanthanides in magnesium alloys by ion chromatography [J].
AlShawi, AW ;
Dahl, R .
ANALYTICA CHIMICA ACTA, 1996, 333 (1-2) :23-30
[3]  
Blythe AN, 2000, ELECTROANAL, V12, P16, DOI 10.1002/(SICI)1521-4109(20000101)12:1<16::AID-ELAN16>3.3.CO
[4]  
2-Q
[5]   The silver electrode in square-wave anodic stripping voltammetry. Determination of Pb2+ without removal of oxygen [J].
Brand, M ;
Eshkenazi, I ;
KirovaEisner, E .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4660-4664
[6]   EFFECT OF CU2+ ION ON THE STRUCTURAL STABILITY OF SYNTHETIC HYDROXYAPATITE [J].
BRUCKNER, S ;
LUSVARDI, G ;
MENABUE, L ;
SALADINI, M .
JOURNAL OF MATERIALS CHEMISTRY, 1993, 3 (07) :715-719
[7]   Determination of reduced glutathione using an amperometric carbon paste electrode chemically modified with TTF-TCNQ [J].
Calvo-Marzal, P ;
Chumbimuni-Torres, KY ;
Höehr, NF ;
Neto, GD ;
Kubota, LT .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 100 (03) :333-340
[8]   Voltammetry determination of trace manganese with pretreatment glassy carbon electrode by linear sweep voltammetry [J].
Di, JW ;
Zhang, F .
TALANTA, 2003, 60 (01) :31-36
[9]   Square-wave voltammetric determination of paraquat at carbon paste electrode modified with hydroxyapatite [J].
El Mhanunedi, Moulay Abderrahim ;
Bakasse, Mina ;
Chtaini, Abdelilah .
ELECTROANALYSIS, 2007, 19 (16) :1727-1733
[10]  
Elliott JC., 1994, STRUCTURE CHEM APATI, DOI DOI 10.1016/B978-0-444-81582-8.50008-0