Towards cardiac C-arm computed tomography

被引:92
作者
Lauritsch, Guenter [1 ]
Boese, Jan
Wigstroem, Lars
Kemeth, Herbert
Fahrig, Rebecca
机构
[1] Siemens AG, Med Solut, D-91301 Forchheim, Germany
[2] Stanford Univ, Sch Med, Stanford, CA 94305 USA
关键词
adaptive filtering; cardiac imaging; C-arm computed tomography (CT); dynamic imaging; retrospective gating;
D O I
10.1109/TMI.2006.876166
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cardiac interventional procedures would benefit tremendously from sophisticated three-dimensional image guidance. Such procedures are typically performed with C-arm angiography systems, and tomographic imaging is currently available only by using preprocedural computed tomography (CT) or magnetic resonance imaging (MRI) scans. Recent developments in C-arm CT (Angiographic CT) allow three-dimensional (3-D) imaging of low contrast details with angiography imaging systems for noncardiac applications. We propose a new approach for cardiac imaging that takes advantage of this improved contrast resolution and is based on intravenous contrast injection. The method is an analogue to multisegment reconstruction in cardiac CT adapted to the much slower rotational speed of C-arm CT. Motion of the heart is considered in the reconstruction process by retrospective electrocardiogram (ECG)-gating, using only projections acquired at a similar heart phase. A series of N almost identical rotational acquisitions is performed at different heart phases to obtain a complete data set at a minimum temporal resolution of 1 IN of the heart cycle time. First results in simulation, using an experimental phantom, and in preclinical in vivo studies showed that excellent image quality can be achieved.
引用
收藏
页码:922 / 934
页数:13
相关论文
共 20 条
  • [1] In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    Achenbach, S
    Ropers, D
    Holle, J
    Muschiol, G
    Daniel, WG
    Moshage, W
    [J]. RADIOLOGY, 2000, 216 (02) : 457 - 463
  • [2] Benndorf G, 2005, AM J NEURORADIOL, V26, P1813
  • [3] 3D tomographic reconstruction of coronary arteries using a precomputed 4D motion field
    Blondel, C
    Vaillant, R
    Malandain, G
    Ayache, N
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) : 2197 - 2208
  • [4] 3-D reconstruction of coronary arterial tree to optimize angiographic visualization
    Chen, SJ
    Carroll, JD
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) : 318 - 336
  • [5] Quantitative analysis of reconstructed 3-D coronary arterial tree and intracoronary devices
    Chen, SYJ
    Carroll, JD
    Messenger, JC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (07) : 724 - 740
  • [6] Fahrig R, 1997, AM J NEURORADIOL, V18, P1507
  • [7] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [8] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [9] HOLZEL A, 2002, THESIS FOCHHOCHSCHUL
  • [10] Kachelriess M, 2000, IEEE T MED IMAGING, V19, P888, DOI 10.1109/42.887837