Defects in rotary nickel-titanium files after clinical use

被引:598
作者
Sattapan, B [1 ]
Nervo, GJ [1 ]
Palamara, JEA [1 ]
Messer, HH [1 ]
机构
[1] Univ Melbourne, Sch Dent Sci, Melbourne, Vic 3000, Australia
关键词
D O I
10.1097/00004770-200003000-00008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to analyze the type and frequency of defects in nickel-titanium rotary endodontic files after routine clinical use, acid to draw conclusions regarding the reasons for failure. All of the files (total: 378, Quantec Series 2000) discarded after normal use from a specialist endodontic practice over 6 months were analyzed. Almost 50% of the files showed some visible defect; 21% were fractured and 28% showed other defects without fracture. Fractured files could be divided into two groups according to the characteristics of the defects observed. Torsional fracture occurred in 55.7% of all fractured files, whereas flexural fatigue occurred in 44.3%. The results indicated that torsional failure, which may be caused by using too much apical force during instrumentation, occurred more frequently than flexural fatigue, which may result from use in curved canals.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 13 条
[1]   The 'Lightspeed' preparation technique evaluated by Swiss clinicians after attending continuing education courses [J].
Barbakow, F ;
Lutz, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) :46-50
[2]  
BROCKHURST P, 1997, AUST ENDOD NEWSLETTE, V23, P13
[3]  
FRICK K, 1997, J DENT RES, V76, P304
[4]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[5]   Assessing apical deformation and transportation following the use of LightSpeed(TM) root-canal instruments [J].
Knowles, KI ;
Ibarrola, JL ;
Christiansen, RK .
INTERNATIONAL ENDODONTIC JOURNAL, 1996, 29 (02) :113-117
[6]  
Laustren L, 1996, J DENT RES, V75, P384
[7]   Cyclic fatigue testing of nickel-titanium endodontic instruments [J].
Pruett, JP ;
Clement, DJ ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1997, 23 (02) :77-85
[8]   Torque during canal instrumentation using rotary nickel-titanium files [J].
Sattapan, B ;
Palamara, JEA ;
Messer, HH .
JOURNAL OF ENDODONTICS, 2000, 26 (03) :156-160
[9]  
SERENE TP, 1995, NICKEK TITANIUM INST
[10]   AN ANALYSIS OF CLINICAL BREAKAGE OF ROOT-CANAL INSTRUMENTS [J].
SOTOKAWA, T .
JOURNAL OF ENDODONTICS, 1988, 14 (02) :75-82