Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics

被引:29
作者
Arvand, A [1 ]
Hahn, N [1 ]
Hormes, M [1 ]
Akdis, M [1 ]
Martin, M [1 ]
Reul, H [1 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, D-5100 Aachen, Germany
关键词
rotary blood pump; impeller design comparison; computational fluid dynamics; hydraulic and hemolytic properties;
D O I
10.1111/j.1525-1594.2004.07379.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A mixed-flow blood pump for long-term applications has been developed at the Helmholtz-Institute in Aachen, Germany. Central features of this implantable pump are a centrally integrated motor, a blood-immersed mechanical bearing, magnetic coupling of the impeller, and a shrouded impeller, which allows a relatively wide clearance. The aim of the study was a numerical analysis of hydraulic and hemolytic properties of different impeller design configurations. In vitro testing and numerical simulation techniques (computational fluid dynamics [CFD]) were applied to achieve a comprehensive overview. Pressure-flow charts were experimentally measured in a mock loop in order to validate the CFD data. In vitro hemolysis tests were performed at the main operating point of each impeller design. General flow patterns, pressure-flow charts, secondary flow rates, torque, and axial forces on the impeller were calculated by means of CFD. Furthermore, based on streak line techniques, shear stress (stress loading), exposure times, and volume percentage with critical stress loading have been determined. Comparison of CFD data with pressure head measurements showed excel-lent agreement. Also, impressive trend conformity was observed between in-vitro hemolysis results and numerical data. Comparison of design variations yielded clear trends and results. Design C revealed the best hydraulic and hemolytic properties and was chosen as the final design for the mixed-flow rotary blood pump.
引用
收藏
页码:892 / 898
页数:7
相关论文
共 9 条
[1]  
Akdis M., 2002, International Journal of Artificial Organs, V25, P666
[2]  
APEL J, 2002, THESIS RWTH AACHEN A
[3]  
Arvand A., 2002, International Journal of Artificial Organs, V25, P695
[4]  
ARVAND A, 2003, ARTIF ORGANS, V27, P367
[5]  
Bludszuweit C., 1994, THESIS U STRATHCLYDE
[6]  
*CFX TASCFL, TASCFL US DOC 2002
[7]  
JONSON W, 1973, ENG PLASTICY
[8]   Shear stress related blood damage in laminar Couette flow [J].
Paul, R ;
Apel, J ;
Klaus, S ;
Schügner, F ;
Schwindke, P ;
Reul, H .
ARTIFICIAL ORGANS, 2003, 27 (06) :517-529
[9]  
PAUL R, 2000, THESIS RWTH AACHEN A