Contrast-enhanced MR angiography in the preoperative evaluation of living kidney donors.

被引:12
作者
Steinborn, M
Wintersperger, BJ
Heck, A
Theodorakis, J
Waggershauser, T
Hillebrand, GF
Reiser, M
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Radiol Diagnost, D-81377 Munich, Germany
[2] Univ Munich, Urol Klin, Munich, Germany
[3] Univ Munich, Med Klin 1, Munich, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 171卷 / 04期
关键词
kidney transplantation; living donor; renal angiography; MR angiography;
D O I
10.1055/s-1999-254
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare Gadolinium-enhanced MR angiography with conventional DSA in the preoperative evaluation of living kidney donors. Material and Methods: 27 potential living kidney donors were examined with contrast-enhanced MR angiography after conventional angiography. The MR angiograms were evaluated for the number of renal arteries, the presence of early arterial branching and vascular pathologies by two independent readers. The results were compared with those of selective conventional angiography and intraoperative findings. Results: Conventional angiography detected 14 accessory renal arteries. Reader A detected 13 of 14 accessory arteries with no false positive result (sensitivity 93 %, specificity 100 %). Reader B detected 11 of 14 accessory vessels with one false positive finding (sensitivity 79 %, specificity 98 %). Early arterial branching was detected by both readers in 9 of 12 vessels with no false positive result (sensitivity 75%, specificity 100%). None of the patients had additional vascular pathology. Discussion: Gadolinium-enhanced MR angiography is a non-invasive alternative to conventional angiography in the preoperative evaluation of living kidney donors. In order to achieve high accuracy in detecting accessory renal arteries and early arterial branching extensive experience with the method and the specific preoperative needs is required. Selective conventional angiography is still superior in detecting very small accessory vessels and early arterial branching.
引用
收藏
页码:313 / 318
页数:6
相关论文
共 22 条
[1]   RENAL VASCULATURE IN POTENTIAL RENAL-TRANSPLANT DONORS - COMPARISON OF MR-IMAGING AND DIGITAL SUBTRACTION ANGIOGRAPHY [J].
ADAMIS, MK ;
GOLDSZER, RC ;
PULDE, MF ;
SAX, EJ ;
EDELMAN, RR .
RADIOLOGY, 1995, 197 (02) :467-472
[2]   THE LIVING DONOR IN KIDNEY-TRANSPLANTATION [J].
BAY, WH ;
HEBERT, LA .
ANNALS OF INTERNAL MEDICINE, 1987, 106 (05) :719-727
[3]  
DAAR AS, 1997, TRANSPLANT REV, V11, P95
[4]   RENAL MAGNETIC-RESONANCE ANGIOGRAPHY IN THE PREOPERATIVE DETECTION OF SUPERNUMERARY RENAL-ARTERIES IN POTENTIAL KIDNEY DONORS [J].
DEBATIN, JF ;
SOSTMAN, HD ;
KNELSON, M ;
ARGABRIGHT, M ;
SPRITZER, CE .
INVESTIGATIVE RADIOLOGY, 1993, 28 (10) :882-889
[5]   First clinical results of ultrafast, gadolinium-enhanced dual-phase 3D MR-angiography in the abdomen. [J].
Gaa, J ;
Laub, G ;
Edelman, RR ;
Georgi, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (02) :135-139
[6]  
Gourlay WA, 1995, TRANSPLANTATION, V60, P1363
[7]   Ultrafast contrast-enhanced 3D MR angiography of the aorta and renal arteries in apnoea [J].
Hany, TF ;
Pfammatter, T ;
Schmidt, M ;
Leung, DA ;
Debatin, JF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (05) :397-405
[8]  
HILLEBRAND GF, 1996, TRANSPLANTATIONSMEDI, V8, P101
[9]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981
[10]   Thoracic aorta: Comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging [J].
Krinsky, GA ;
Rofsky, NM ;
DeCorato, DR ;
Weinreb, JC ;
Earls, JP ;
Flyer, MA ;
Galloway, AC ;
Colvin, SB .
RADIOLOGY, 1997, 202 (01) :183-193