Influence of intra-fractional breathing movement in step-and-shoot IMRT

被引:46
作者
Schaefer, M
Münter, MW
Thilmann, C
Sterzing, F
Haering, P
Combs, SE
Debus, J
机构
[1] DKFZ, German Canc Res Ctr, Clin Cooperat Unit Radiotherapy, D-69120 Heidelberg, Germany
[2] DKFZ, German Canc Res Ctr, Dept Med Phys Radiotherapy, D-69120 Heidelberg, Germany
关键词
D O I
10.1088/0031-9155/49/12/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Efforts have been made to extend the application of intensity-modulated radiotherapy to a variety of organs. One of the unanswered questions is whether breathing-induced organ motion may lead to a relevant over-or underdosage, e.g., in treatment plans for the irradiation of lung cancer. Theoretical considerations have been made concerning the different kinds of IMRT but there is still a lack of experimental data. We examined 18 points in a fraction of a clinical treatment plan of a NSCLC delivered in static IMRT with a new phantom and nine ionization chambers. Measurements were performed at a speed of 12 and 16 breathing cycles per minute. The dose differences between static points and moving target points ranged between -2.4% and +5.5% (mean: +0.2%, median: -0.1%) when moving with 12 cycles min(-1) and between -3.6% and +5.0% (mean: -0.4%, median: -0.6%) when moving with 16 cycles min(-1). All differences of measurements with and without movements were below 5%, with one exception. In conclusion, our results underline that at least in static IMRT breathing effects (concerning target dose coverage) due to interplay effects between collimator leaf movement and target movement are of secondary importance and will not reduce the clinical value of IMRT in the step-and-shoot technique for irradiation of thoracic targets.
引用
收藏
页码:N175 / N179
页数:5
相关论文
共 21 条
[2]   Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation [J].
Bortfeld, T ;
Jokivarsi, K ;
Goitein, M ;
Kung, J ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) :2203-2220
[3]  
Chao KSC, 2000, INT J CANCER, V90, P92, DOI 10.1002/(SICI)1097-0215(20000420)90:2<92::AID-IJC5>3.0.CO
[4]  
2-9
[5]   Intensity modulated versus non-intensity modulated radiotherapy in the treatment of the left breast and upper internal mammary lymph node chain: a comparative planning study [J].
Cho, BCJ ;
Hurkmans, CW ;
Damen, EMF ;
Zijpa, LJ ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (02) :127-136
[6]  
Debus J, 2002, FRONT RADIAT THER ON, V36, P25
[7]   Intensity-modulated radiotherapy of head-and-neck cancer: Encouraging early results [J].
Eisbruch, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (01) :1-3
[8]  
Eisbruch Avraham, 2002, Med Dosim, V27, P99, DOI 10.1016/S0958-3947(02)00091-2
[9]   An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments [J].
Jiang, SB ;
Pope, C ;
Al Jarrah, KM ;
Kung, JH ;
Bortfeld, T ;
Chen, GTY .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (12) :1773-1784
[10]   Organ motion and its management [J].
Langen, KM ;
Jones, DTL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01) :265-278