Therapeutic ratio of hydrofluoroalkane and chlorofluorocarbon formulations of fluticasone propionate

被引:23
作者
Fowler, SJ [1 ]
Orr, LC [1 ]
Sims, EJ [1 ]
Wilson, AM [1 ]
Currie, GP [1 ]
McFarlane, L [1 ]
Lipworth, BJ [1 ]
机构
[1] Univ Dundee, Ninewells Hosp & Med Sch, Dept Clin Pharmacol & Therapeut, Asthma & Allergy Res Grp, Dundee DD1 9SY, Scotland
关键词
aerosol propellants; asthma; bronchial hyperreactivity; corticosteroids; fluticasone;
D O I
10.1378/chest.122.2.618
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To compare the therapeutic ratio of chlorofluorocarbon (CFC) and hydrofluoro-alkane-134a (HFA) formulations of fluticasone propionate (FP). Methods: We performed a randomized, placebo-controlled, crossover study comparing 6 weeks of treatment with FP using 500 mug/d and 1,000 mug/d formulations of CFC and HFA. The primary end points were provocative dose of methacholine causing a 20% fall in FEV1 (PD20) and overnight urinary cortisol/creatinine excretion. Results: Eighteen patients with mild-to-moderate asthma and geometric mean (SEM) PD20 of 82.3 mug (19.2 mug) completed the study. All treatments significantly improved PD20 values and morning peak expiratory flow vs placebo, while 1,000 mug/d was significantly better than 500 mug/d for the CFC formulation of FP (CFC-FP) but not the HFA formulation of FP (HFA-FP). Only, 1,000 mug/d of CFC-FP caused significant suppression of overnight urinary cortisol/creatinine compared to placebo. There were no differences between formulations at dither dose. Conclusions: The increased airway benefit with CFC-FP > 500 mug/d was offset by greater systemic effects. Although HFA-FP had fewer systemic effects than CFC-FP at 1,000 mug/d, there. was no benefit to increasing HFA-FP to > 500 mug/d.
引用
收藏
页码:618 / 623
页数:6
相关论文
共 23 条
[1]  
[Anonymous], 1987, Am Rev Respir Dis, V136, P1285
[2]   Clinical efficacy and safety of fluticasone propionate 1 mg twice daily administered via a HFA 134a pressurized metered dose inhaler to patients with severe asthma [J].
Ayres, JG ;
Millar, AB ;
Sykes, AP .
RESPIRATORY MEDICINE, 2000, 94 :S42-S50
[3]   MEASUREMENT OF AIRWAY RESPONSIVENESS TO METHACHOLINE - RELATIVE IMPORTANCE OF THE PRECISION OF DRUG DELIVERY AND THE METHOD OF ASSESSING RESPONSE [J].
BEACH, JR ;
YOUNG, CL ;
AVERY, AJ ;
STENTON, SC ;
DENNIS, JH ;
WALTERS, EH ;
HENDRICK, DJ .
THORAX, 1993, 48 (03) :239-243
[4]   Comparison of pharmacokinetics and systemic effects of inhaled fluticasone propionate in patients with asthma and healthy volunteers: a randomised crossover study [J].
Brutsche, MH ;
Brutsche, IC ;
Munavvar, M ;
Langley, SJ ;
Masterson, CM ;
Daley-Yates, PT ;
Brown, R ;
Custovic, A ;
Woodcock, A .
LANCET, 2000, 356 (9229) :556-561
[5]   Pharmaceutical transition to non-CFC pressurized metered dose inhalers [J].
Cripps, A ;
Riebe, M ;
Schulze, M ;
Woodhouse, R .
RESPIRATORY MEDICINE, 2000, 94 :S3-S9
[6]   Comparison of the systemic availability of fluticasone propionate in healthy volunteers and patients with asthma [J].
Daley-Yates, PT ;
Tournant, J ;
Kunka, RL .
CLINICAL PHARMACOKINETICS, 2000, 39 (Suppl 1) :39-45
[7]   Comparison of the systemic effects of fluticasone propionate and budesonide given by dry powder inhaler in healthy and asthmatic subjects [J].
Harrison, TW ;
Wisniewski, A ;
Honour, J ;
Tattersfield, AE .
THORAX, 2001, 56 (03) :186-191
[8]   Dose-response relation of inhaled fluticasone propionate in adolescents and adults with asthma: meta-analysis [J].
Holt, S ;
Suder, A ;
Weatherall, M ;
Cheng, S ;
Shirtcliffe, P ;
Beasley, R .
BRITISH MEDICAL JOURNAL, 2001, 323 (7307) :253-+
[9]   Effect of differing doses of inhaled budesonide on markers of airway inflammation in patients with mild asthma [J].
Jatakanon, A ;
Kharitonov, S ;
Lim, S ;
Barnes, PJ .
THORAX, 1999, 54 (02) :108-114
[10]   Increased exhaled nitric oxide in asthma is mainly derived from the lower respiratory tract [J].
Kharitonov, SA ;
Chung, KF ;
Evans, D ;
OConnor, BJ ;
Barnes, PJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (06) :1773-1780