Determination of the size distribution of lecithin liposomes: A comparative study using freeze fracture, cryoelectron microscopy and dynamic light scattering

被引:119
作者
Egelhaaf, SU
Wehrli, E
Muller, M
Adrian, M
Schurtenberger, P
机构
[1] ETH ZURICH,LAB ELEKTRONENMIKROSKOPIE 1,CH-8092 ZURICH,SWITZERLAND
[2] UNIV LAUSANNE,LAB ANAL ULTRASTRUCT,CH-1015 DORIGNY,SWITZERLAND
[3] ETH ZENTRUM,INST POLYMERE,CH-8092 ZURICH,SWITZERLAND
来源
JOURNAL OF MICROSCOPY-OXFORD | 1996年 / 184卷
关键词
cryotransmission electron microscopy; dynamic light scattering; freeze fracture electron microscopy; liposomes; size distribution; vesicles;
D O I
10.1046/j.1365-2818.1996.1280687.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
The size distribution of liposomes is often determined using freeze fracture, cryoelectron microscopy or dynamic light scattering. However, the resulting size distributions do not directly coincide owing to the different weighting of the techniques. We present several methods which correct for these effects and allow a comparison of liposome size distributions as obtained by freeze fracture, cryoelectron microscopy or dynamic light scattering. These methods are based on theoretical models for the weighting of the size distribution of liposomes, which result from the preparation procedure for freeze fracture electron microscopy and from the measurement by dynamic light scattering. The proposed transformation methods are then experimentally tested with a sample of lecithin liposomes, whose size distribution was determined by dynamic light scattering, freeze fracture and cryoelectron microscopy. Furthermore, the weaknesses of the experimental techniques and hence of the resulting size distributions are discussed.
引用
收藏
页码:214 / 228
页数:15
相关论文
共 50 条
[1]   CRYO-ELECTRON MICROSCOPY OF VIRUSES [J].
ADRIAN, M ;
DUBOCHET, J ;
LEPAULT, J ;
MCDOWALL, AW .
NATURE, 1984, 308 (5954) :32-36
[2]  
ANDERSSEN RS, 1980, APPLICATIONS NUMERIC, P19
[3]   THEORY OF DYNAMIC LIGHT-SCATTERING FROM POLYDISPERSE SYSTEMS [J].
ARAGON, SR ;
PECORA, R .
JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (06) :2395-2404
[4]  
BACH G, 1976, Biometrische Zeitschrift, V18, P407
[5]  
BACH G, 1967, QUANTITATIVE METHODS, P23
[6]   CONTROLLED ENVIRONMENT VITRIFICATION SYSTEM - AN IMPROVED SAMPLE PREPARATION TECHNIQUE [J].
BELLARE, JR ;
DAVIS, HT ;
SCRIVEN, LE ;
TALMON, Y .
JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1988, 10 (01) :87-111
[7]  
Berne BJ, 1976, Dynamic Light Scattering
[8]  
Bevington P. R., 2002, Data Reduction and Error Analysis For the Physical Sciences, V3rd
[9]  
BLODNER R, 1984, J MICROSC-OXFORD, V135, P61, DOI 10.1111/j.1365-2818.1984.tb04649.x
[10]  
COLEMAN R, 1982, Biometrical Journal, V24, P273, DOI 10.1002/bimj.4710240313