Characterization of switched direct current gas sampling glow discharge ionization source for the time-of-flight mass spectrometer

被引:26
作者
Guzowski, JP [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1039/a906210f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A variable frequency, switched, direct-current gas sampling glow discharge ionization source was interfaced to an orthogonally extracted time-of-flight mass spectrometer for the purpose of dynamically generating atomic and molecular mass spectra of halogenated hydrocarbons. The plasma duty cycle is 50% in each mode of operation. The operating mode is selected simply by switching the polarity of voltage applied to the sample-introduction plate. The self-igniting helium discharge is contained within the first vacuum stage of the differentially pumped spectrometric interface. Both atomic and molecular mass spectra could be obtained with similar ion-optical lens settings, with the exception of the steering plate potential, which had to be alternated between two values (at the plasma switching frequency). A range of discharge switching rates can be used, although a non-linear drop in the modulated signal occurs with frequency. Switching rates above 100 Hz appears to be impractical with current experimental apparatus. Long-term temporal stability of the atomic (Br-79(+)) and molecular ((CHBr2+)-C-172) signals was measured over a period greater than 1 h, with an overall precision of 13.3 and 6.1% RSD, respectively. The Br-79(+)/Br-81(+) isotope ratio precision was 1.1% RSD over this period, while the (CHBr2+)-C-172/(CHBr2+)-C-173 molecular ratio was determined to be 1.6% RSD. The precision of the isotope and ionic ratios are counting statistics limited. The atomic detection limit is in the range 3-110 pg s(-1) (as the halogen) and 15-250 pg s(-1) (molecular) for analytes manually introduced into an exponential-dilution sample-introduction device, with boxcar averagers being employed for data collection. A variety of chlorinated hydrocarbons were introduced into the discharge via the flow cell, and it was possible to differentiate (or speciate) the compounds based on their Cl-35(+)/C-12(+) elemental ratios with a correlation coefficient (R) of 0.995.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 55 条
[1]  
[Anonymous], 1983, 8 PEAK IND MASS SPEC
[2]   HOLLOW-ANODE PLASMA EXCITATION SOURCE FOR ATOMIC EMISSION-SPECTROMETRY [J].
BALLOU, NE ;
STYRIS, DL ;
HARNLY, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (08) :1141-1143
[3]   OBSERVATION OF PENNING IONIZATION IN SR/NE DISCHARGE BY THE OPTOGALVANIC EFFECT [J].
BENAMAR, A ;
EREZ, G ;
FASTIG, S ;
SHUKER, R .
APPLIED OPTICS, 1984, 23 (24) :4529-4531
[5]  
BORER MW, 1991, SPECTROCHIM ACTA REV, V14, P463
[6]   STATE-OF-THE-ART OF GLOW-DISCHARGE LAMP SPECTROMETRY - PLENARY LECTURE [J].
BROEKAERT, JAC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (06) :537-542
[7]   A GAS-SAMPLING GLOW-DISCHARGE COUPLED TO HYDRIDE GENERATION FOR THE ATOMIC SPECTROMETRIC DETERMINATION OF ARSENIC [J].
BROEKAERT, JAC ;
PEREIRO, R ;
STARN, TK ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (10) :1207-1220
[8]   A COMPARATIVE-STUDY OF 3 MICROWAVE-INDUCED PLASMA SOURCES FOR ATOMIC-EMISSION SPECTROMETRY .2. EVALUATION OF THEIR ATOMIZATION EXCITATION CAPABILITIES FOR CHLORINATED HYDROCARBONS [J].
CAMUNAAGUILAR, JF ;
PEREIROGARCIA, R ;
SANCHEZURIA, JE ;
SANZMEDEL, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (06) :545-554
[9]   DESIGN, OPTIMIZATION, AND UTILIZATION OF A MICROWAVE INDUCED HELIUM PLASMA GAS-CHROMATOGRAPHIC DETECTOR IN AN INDUSTRIAL LABORATORY [J].
CERBUS, CS ;
GLUCK, SJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (1-2) :387-397
[10]   CHARACTERIZATION OF AN ANNULAR HELIUM INDUCTIVELY COUPLED PLASMA GENERATED IN A LOW-GAS-FLOW TORCH [J].
CHAN, SK ;
MONTASER, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (04) :591-597