Production and certification of NIST Standard Reference Material 2372 Human DNA Quantitation Standard

被引:30
作者
Kline, Margaret C. [1 ]
Duewer, David L. [2 ]
Travis, John C. [1 ]
Smith, Melody V. [1 ]
Redman, Janette W. [1 ]
Vallone, Peter M. [1 ]
Decker, Amy E. [1 ]
Butler, John M. [1 ]
机构
[1] Natl Inst Stand & Technol, Div Biochem Sci, Gaithersburg, MD 20899 USA
[2] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
关键词
Certified reference material (CRM); Decadic attenuance; Forensic; Human identity; Interlaboratory comparison; Short tandem repeat (STR) multiplex assay; Standard Reference Material (SRM); UV/visible absorbance spectrophotometry; FORENSIC SAMPLES; PCR ASSAY; QUANTIFICATION METHODS; MIXED STAIN; OLIGONUCLEOTIDES; SPECTROSCOPY; PERFORMANCE; PHOSPHORUS;
D O I
10.1007/s00216-009-2782-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Modern highly multiplexed short tandem repeat (STR) assays used by the forensic human-identity community require tight control of the initial amount of sample DNA amplified in the polymerase chain reaction (PCR) process. This, in turn, requires the ability to reproducibly measure the concentration of human DNA, [DNA], in a sample extract. Quantitative PCR (qPCR) techniques can determine the number of intact stretches of DNA of specified nucleotide sequence in an extremely small sample; however, these assays must be calibrated with DNA extracts of well-characterized and stable composition. By 2004, studies coordinated by or reported to the National Institute of Standards and Technology (NIST) indicated that a well-characterized, stable human DNA quantitation certified reference material (CRM) could help the forensic community reduce within-and among-laboratory quantitation variability. To ensure that the stability of such a quantitation standard can be monitored and that, if and when required, equivalent replacement materials can be prepared, a measurement of some stable quantity directly related to [DNA] is required. Using a long-established conventional relationship linking optical density (properly designated as decadic attenuance) at 260 nm with [DNA] in aqueous solution, NIST Standard Reference Material (SRM) 2372 Human DNA Quantitation Standard was issued in October 2007. This SRM consists of three quite different DNA extracts: a single-source male, a multiple-source female, and a mixture of male and female sources. All three SRM components have very similar optical densities, and thus very similar conventional [DNA]. The materials perform very similarly in several widely used gender-neutral assays, demonstrating that the combination of appropriate preparation methods and metrologically sound spectrophotometric measurements enables the preparation and certification of quantitation [DNA] standards that are both maintainable and of practical utility.
引用
收藏
页码:1183 / 1192
页数:10
相关论文
共 35 条
[1]  
[Anonymous], 1989, ANALYST, V114, P1693, DOI DOI 10.1039/AN9891401693
[2]  
[Anonymous], 1994, Accuracy (trueness and precision) of measurement methods and results - Part 1: General principies and defmitions
[3]  
*APPL BIOS, 2003, QUANT HUM DNA QUANT
[4]  
BURKE RW, 1977, NIST SPECIAL PUBLICA
[5]  
BUTLER JM, 2006, INT C SER, V1288, P628
[6]  
Duewer DL, 2001, J FORENSIC SCI, V46, P1199
[7]   Use of elemental analysis to determine comparative performance of established DNA quantification methods [J].
English, Claire A. ;
Merson, Sheila ;
Keer, Jacquie T. .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4630-4633
[8]   Traceable phosphorus measurements by ICP-OES and HPLC for the quantitation of DNA [J].
Holden, Marcia J. ;
Rabb, Savelas A. ;
Tewari, Yadu B. ;
Winchester, Michael R. .
ANALYTICAL CHEMISTRY, 2007, 79 (04) :1536-1541
[9]  
Killeen AA, 1997, CLIN LAB MED, V17, P1
[10]   NIST mixed stain study 3: DNA quantitation accuracy and its influence on short tandem repeat multiplex signal intensity [J].
Kline, MC ;
Duewer, DL ;
Redman, JW ;
Butler, JM .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2463-2469