NADH and glutamate on-line sensors using Os-gel-HRP/GC electrodes modified with NADH oxidase and glutamate dehydrogenase

被引:36
作者
Liu, ZM
Niwa, O
Horiuchi, T
Kurita, R
Torimitsu, K
机构
[1] NTT Basic Res Labs, Atsugi, Kanagawa 2430198, Japan
[2] NTT Adv Technol, Atsugi, Kanagawa 2430198, Japan
关键词
NADH and glutamate on-line sensor; NADH oxidase; glutamate dehydrogenase; osmium-poly(vinylpyridine) wired horseradish; peroxidase/glassy carbon electrode;
D O I
10.1016/S0956-5663(99)00041-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have developed a highly sensitive and selective on-line biosensor for detecting the reduced form of nicotinamide adenine dinucleotide (NADH) produced by the enzymatic reactions of dehydrogenases with Various substrates such as glutamate. The sensor consists of a glassy carbon electrode modified with an osmium-polyvinylpyridine-based bottom layer containing horseradish peroxidase, and a bovine serum albumin (BSA)-gluteraldehyde (Glut) top layer containing NADH oxidase (NOX) or glutamate dehydrogenase (GluDH) and NOX. We assembled the modified electrode in a thin-layer radial flow cell and sample solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the NADH sensor by adjusting the glutaraldehyde amount in the immobilized layer, the applied potential and the pH of buffer solution. We examined the flow-rate effect on the current response and the conversion efficiency of NADH at the modified electrode. As a result, we achieved a sensitivity of 48.8 nA cm(-2) mu M-1, a detectable concentration range of 25 nM similar to 10 mu M and a detection limit of 20 nM (S/N = 3) for the NADH sensor. The interference from ascorbic acid and other electroactive interferents can be greatly reduced since the sensor can be operated below 0 mV versus Ag/AgCl. The NADH sensor is relatively stable since it retains 70% of its original response after I month if stored at 2-8 degrees C in a dry state after use. Furthermore, we fabricated a glutamate sensor by coimmobilizing GluDH and NOX in the BSA-Glut top layer. The detectable glutamate concentration range is from 0.1 to 10 mu M and the detection limit is 0.1 mu M (S/N = 3). Our glutamate dehydrogenase-based sensor offers good selectivity as regards other amino acids. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:631 / 638
页数:8
相关论文
共 39 条
[1]   INTRACELLULAR ANALYSIS WITH AN IMMOBILIZED-ENZYME GLUCOSE ELECTRODE HAVING A 2-MU-M DIAMETER AND SUBSECOND RESPONSE-TIMES [J].
ABE, T ;
LAU, YY ;
EWING, AG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (19) :7421-7423
[2]   PREPARATION AND CHARACTERIZATION OF A FRAGILE ENZYME IMMOBILIZED CARBON PASTE ELECTRODE [J].
AMINE, A ;
KAUFFMANN, JM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1992, 28 (1-2) :117-125
[3]   ONLINE MEASUREMENT OF BRAIN GLUTAMATE WITH AN ENZYME/POLYMER-COATED TUBULAR ELECTRODE [J].
BERNERS, MOM ;
BOUTELLE, MG ;
FILLENZ, M .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2017-2021
[4]   STUDY OF ELECTROCHEMICAL OXIDATION OF REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE [J].
BLAEDEL, WJ ;
JENKINS, RA .
ANALYTICAL CHEMISTRY, 1975, 47 (08) :1337-1343
[5]   DETERMINATION OF L-GLUTAMATE AND L-GLUTAMINE BY FLOW-INJECTION ANALYSIS AND CHEMILUMINESCENCE DETECTION - COMPARISON OF AN ENZYME COLUMN AND ENZYME MEMBRANE SENSOR [J].
BLANKENSTEIN, G ;
PREUSCHOFF, F ;
SPOHN, U ;
MOHR, KH ;
KULA, MR .
ANALYTICA CHIMICA ACTA, 1993, 271 (02) :231-237
[6]   ELECTROCHEMICAL OXIDATION OF NADH - KINETIC CONTROL BY PRODUCT INHIBITION AND SURFACE COATING [J].
BLANKESPOOR, RL ;
MILLER, LL .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 171 (1-2) :231-241
[7]   CORRELATION BETWEEN LONG-TERM POTENTIATION AND RELEASE OF ENDOGENOUS AMINO-ACIDS FROM DENTATE GYRUS OF ANESTHETIZED RATS [J].
BLISS, TVP ;
DOUGLAS, RM ;
ERRINGTON, ML ;
LYNCH, MA .
JOURNAL OF PHYSIOLOGY-LONDON, 1986, 377 :391-408
[8]   FERRICINIUM ION AS AN ELECTRON-ACCEPTOR FOR OXIDO-REDUCTASES [J].
CASS, AEG ;
DAVIS, G ;
GREEN, MJ ;
HILL, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 190 (1-2) :117-127
[9]   ENZYME SENSORS FOR L-AMINO-ACID BASED ON ELECTROCHEMICAL DETECTION OF NADH [J].
CHANG, HC ;
UENO, A ;
YAMADA, H ;
MATSUE, T ;
UCHIDA, I .
DENKI KAGAKU, 1990, 58 (12) :1211-1212
[10]   AN ENZYME-MODIFIED MICROELECTRODE THAT DETECTS CHOLINE INJECTED LOCALLY INTO BRAIN-TISSUE [J].
GARGUILO, MG ;
MICHAEL, AC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (25) :12218-12219