Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry - A human volunteer study

被引:148
作者
Barker, Steven J. [1 ]
Curry, Jeremy [1 ]
Redford, Daniel [1 ]
Morgan, Scott [1 ]
机构
[1] Univ Arizona, Coll Med, Dept Anesthesiol, Tucson, AZ 85724 USA
关键词
D O I
10.1097/00000542-200611000-00008
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. Methods: Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. Results: The Rad-57 measured carboxyhemoglobin with an uncertainty of +/- 2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. Conclusion: The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.
引用
收藏
页码:892 / 897
页数:6
相关论文
共 17 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   BENZOCAINE-INDUCED METHEMOGLOBINEMIA IN AN ADULT - ACCURACY OF PULSE OXIMETRY WITH METHEMOGLOBINEMIA [J].
ANDERSON, ST ;
HAJDUCZEK, J ;
BARKER, SJ .
ANESTHESIA AND ANALGESIA, 1988, 67 (11) :1099-1101
[3]   Acquired methemoglobinemia - A retrospective series of 138 cases at 2 teaching hospitals [J].
Ash-Bernal, R ;
Wise, R ;
Wright, SM .
MEDICINE, 2004, 83 (05) :265-273
[4]   THE EFFECT OF CARBON-MONOXIDE INHALATION ON PULSE OXIMETRY AND TRANS-CUTANEOUS PO2 [J].
BARKER, SJ ;
TREMPER, KK .
ANESTHESIOLOGY, 1987, 66 (05) :677-679
[5]   EFFECTS OF METHEMOGLOBINEMIA ON PULSE OXIMETRY AND MIXED VENOUS OXIMETRY [J].
BARKER, SJ ;
TREMPER, KK ;
HYATT, J .
ANESTHESIOLOGY, 1989, 70 (01) :112-117
[6]   THE ANTIDOTAL ACTION OF SODIUM-NITRITE AND SODIUM THIOSULFATE AGAINST CYANIDE POISONING [J].
BASKIN, SI ;
HOROWITZ, AM ;
NEALLEY, EW .
JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 32 (04) :368-375
[7]   Severe carbon monoxide poisoning during desflurane anesthesia [J].
Berry, PD ;
Sessler, DI ;
Larson, MD .
ANESTHESIOLOGY, 1999, 90 (02) :613-616
[8]  
ERSTAD BL, 1992, CLIN PHARMACY, V11, P800
[9]   Critical rebound methemoglobinemia after methylene blue treatment: Case report [J].
Fitzsimons, MG ;
Gaudette, RR ;
Hurford, WE .
PHARMACOTHERAPY, 2004, 24 (04) :538-540
[10]   Pulse oximetry in severe carbon monoxide poisoning [J].
Hampson, NB .
CHEST, 1998, 114 (04) :1036-1041