Treatment of complex proximal tibia fractures with the Less Invasive Skeletal Stabilization System

被引:89
作者
Ricci, WM [1 ]
Rudzki, JR [1 ]
Borrelli, J [1 ]
机构
[1] Washington Univ, Sch Med, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63110 USA
关键词
proximal tibia; fracture; minimally invasive; LISS;
D O I
10.1097/00005131-200409000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Proximal tibia fractures with metaphyseal comminution present a difficult treatment challenge. The Less Invasive Skeletal Stabilization (LISS) internal fixator system has theoretical advantages (minimally invasive fixed angle construct) for the treatment of these injuries. This report presents clinical results of the LISS system for treatment of complex proximal tibia fractures and illustrates the unique properties of the system. Design: Prospective clinical trial Setting: Level I trauma center. Patients: Twenty-eight consecutive patients with comminuted proximal tibia metaphyseal fractures (41 A3, 4 1 C2, or 41 C3) treated with LISS plates. Outcome Measurements: Healing, fracture alignment, infectious and implant-related complications, and functional outcome based oil the Lower Extremity Measure (LEM). Results: Average follow-up was 23 months (range 12-48). Thirty-seven of 38 patients healed their fracture after the index procedure. The other heated after implant removal without the need for further fracture repair. Postoperative fracture alignment was satisfactory in 37 of the 38 cases and was maintained in all patients at union. There were no infectious complications. The average LEM score was 88. Conclusions: The LISS internal fixator system can be used successfully to treat complex proximal tibia fractures without the need for additional medial stabilization. Surgeons attempting to use fixed angle internal fixation plating systems should familiarize themselves with the significant technical differences between these and traditional plating systems to assure satisfactory results.
引用
收藏
页码:521 / 527
页数:7
相关论文
共 38 条
[1]
Bal GK, 2000, CLIN ORTHOP RELAT R, P234
[2]
Bohler L., 1958, TREATMENT FRACTURES
[3]
BOLHOFNER BR, 1995, CLIN ORTHOP RELAT R, P75
[4]
Extraosseous blood supply of the tibia and the effects of different plating techniques: A human cadaveric study [J].
Borrelli, J ;
Prickett, W ;
Song, E ;
Becker, D ;
Ricci, W .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (10) :691-695
[5]
A technique for intramedullary nailing of proximal third tibia fractures [J].
Buehler, KC ;
Green, J ;
Woll, TS ;
Duwelius, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (03) :218-223
[6]
Collins A, 2000, SWINE HEALTH PROD, V8, P211
[7]
Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator [J].
Dendrinos, GK ;
Kontos, S ;
Katsenis, D ;
Dalas, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :710-717
[8]
Farouk O, 1997, INJURY, V28, pSA7
[10]
FREEDMAN EL, 1995, CLIN ORTHOP RELAT R, P25