Comparison of real-time quantitative polymerase chain reaction with three other assays for quantitation of hepatitis C virus

被引:19
作者
Enomoto, M
Nishiguchi, S
Shiomi, S
Tanaka, M
Fukuda, K
Ueda, T
Tamori, A
Habu, D
Takeda, T
Yano, Y
Otani, S
机构
[1] Osaka City Univ, Sch Med, Dept Internal Med 3, Abeno Ku, Osaka 5458585, Japan
[2] Osaka City Univ, Sch Med, Dept Biochem 2, Osaka 545, Japan
关键词
amplicor monitor test; branched DNA assay; chronic hepatitis C; core protein; genotypes; hepatitis C virus; interferon; polymerase chain reaction;
D O I
10.1046/j.1440-1746.2001.02542.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Evaluation of serum levels of hepatitis C virus (HCV) is important for predicting the response to interferon treatment and monitoring its therapeutic efficacy. The aim of this study was to evaluate real-time quantitative polymerase chain reaction (PCR) as a method for the measurement of HCV-RNA. Methods: The subjects were 50 patients with chronic hepatitis C: 36 with genotype 1b, eight with genotype 2a, and six with genotype 2b. Samples were tested for HCV-RNA by using real-time quantitative PCR with the ABI Prism 7700 sequence detection system, a branched DNA signal amplification assay, and an Amplicor monitor test; and for HCV core protein by using a fluorescent enzyme immunoassay. Results: The detection range of the real-time quantitative PCR was between 10(1)-10(8) copies/mL of HCV-RNA. Hepatitis C virus RNA was detectable in all 50 samples by the use of real-time quantitative PCR, but was undetectable in 14 samples by the use of a branched DNA assay and in two samples by using the Amplicor monitor test; HCV core protein was undetectable in three samples. A significant correlation was found between the results of real-time quantitative PCR and those of the three other assays: branched DNA assay (r = 0.837, P < 0.0001), Amplicor monitor test (r = 0.853, P < 0.0001), and HCV core protein concentrations (r = 0.549, P < 0.0001). Conclusions: Our results showed that the real-time quantitative PCR was a highly sensitive assay for the measurement of HCV-RNA. (C) 2001 Blackwell Science Asia Pty Ltd.
引用
收藏
页码:904 / 909
页数:6
相关论文
共 31 条
[1]   THE NATURAL-HISTORY OF COMMUNITY-ACQUIRED HEPATITIS-C IN THE UNITED-STATES [J].
ALTER, MJ ;
MARGOLIS, HS ;
KRAWCZYNSKI, K ;
JUDSON, FN ;
MARES, A ;
ALEXANDER, WJ ;
HU, PY ;
MILLER, JK ;
GERBER, MA ;
SAMPLINER, RE ;
MEEKS, EL ;
BEACH, MJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (27) :1899-1905
[2]  
CHAYAMA K, 1991, HEPATOLOGY, V13, P1040
[3]   SINGLE-STEP METHOD OF RNA ISOLATION BY ACID GUANIDINIUM THIOCYANATE PHENOL CHLOROFORM EXTRACTION [J].
CHOMCZYNSKI, P ;
SACCHI, N .
ANALYTICAL BIOCHEMISTRY, 1987, 162 (01) :156-159
[4]   ISOLATION OF A CDNA CLONE DERIVED FROM A BLOOD-BORNE NON-A, NON-B VIRAL-HEPATITIS GENOME [J].
CHOO, QL ;
KUO, G ;
WEINER, AJ ;
OVERBY, LR ;
BRADLEY, DW ;
HOUGHTON, M .
SCIENCE, 1989, 244 (4902) :359-362
[5]   TREATMENT OF CHRONIC HEPATITIS-C WITH RECOMBINANT INTERFERON-ALFA - A MULTICENTER RANDOMIZED, CONTROLLED TRIAL [J].
DAVIS, GL ;
BALART, LA ;
SCHIFF, ER ;
LINDSAY, K ;
BODENHEIMER, HC ;
PERRILLO, RP ;
CAREY, W ;
JACOBSON, IM ;
PAYNE, J ;
DIENSTAG, JL ;
VANTHIEL, DH ;
TAMBURRO, C ;
LEFKOWITCH, J ;
ALBRECHT, J ;
MESCHIEVITZ, C ;
ORTEGO, TJ ;
GIBAS, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 321 (22) :1501-1506
[6]   Accurate quantification of hepatitis C virus (HCV) RNA from all HCV genotypes by using branched-DNA technology [J].
Detmer, J ;
Lagier, R ;
Flynn, J ;
Zayati, C ;
Kolberg, J ;
Collins, M ;
Urdea, M ;
SanchezPescador, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (04) :901-907
[7]  
DI BA, 1989, NEW ENGL J MED, V321, P1506
[8]  
Enomoto M, 2000, HEPATOLOGY, V32, p355A
[9]   Mutations in the nonstructural protein 5A gene and response to interferon in patients with chronic hepatitis C virus 1b infection [J].
Enomoto, N ;
Sakuma, I ;
Asahina, Y ;
Kurosaki, M ;
Murakami, T ;
Yamamoto, C ;
Ogura, Y ;
Izumi, N ;
Marumo, F ;
Sato, C .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (02) :77-81
[10]   A novel method for real time quantitative RT PCR [J].
Gibson, UEM ;
Heid, CA ;
Williams, PM .
GENOME RESEARCH, 1996, 6 (10) :995-1001