Biotinylated polypyrrole films: an easy electrochemical approach for the reagentless immobilization of bacteria on electrode surfaces

被引:26
作者
Da Silva, S
Grosjean, L
Ternan, N
Mailley, P
Livache, T
Cosnier, S
机构
[1] Univ Grenoble 1, CNRS, UMR 5630, Lab Electrochim Organ & Photochim Redox, F-38041 Grenoble 9, France
[2] CEA Grenoble, Grp CREAB, DRFMC S13M EMSI, F-38054 Grenoble 9, France
[3] Univ Ulster, Sch Biol & Environm Sci, Microbial Biotechnol Res Grp, Coleraine BT52 1SA, Londonderry, North Ireland
关键词
biotinylated polypyrrole films; reagentless immobilization; electrode surfaces;
D O I
10.1016/j.bioelechem.2003.09.027
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Biotinylated bacteria were immobilized onto biotin/avidin modified electrode surfaces. Firstly, an electrospotting deposition method, followed by fluorescence microscopy, showed that bacteria were specifically grafted onto a gold surface. Fluorescence intensity versus the quantity of bacteria deposited on the surface was correlated, allowing determination of the microbial saturation point. Secondly, biotinylated bacteria were immobilized onto a glassy carbon macro-electrode in order to assess immobilized bacterial denitrification activity. During a 7-day trial, the modified electrode completely denitrified 5 mM nitrate, with a rate of 1.66 mM/day over the first 3 days. When the same electrode was placed in fresh nitrate solution, the denitrification rate dropped to 0.80 mM/day. Crucially, the immobilized bacteria did not become detached from the electrode during the study. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:297 / 301
页数:5
相关论文
共 17 条
  • [1] [Anonymous], REV MOL BIOTECHNOL, DOI DOI 10.1016/S1389-0352(01)00058-7
  • [2] Anzai J., 1995, ANAL CHEM, V67, P811
  • [3] Cosnier S, 1998, ELECTROANAL, V10, P808, DOI 10.1002/(SICI)1521-4109(199809)10:12<808::AID-ELAN808>3.3.CO
  • [4] 2-B
  • [5] A biotinylated conducting polypyrrole for the spatially controlled construction of an amperometric biosensor
    Cosnier, S
    Stoytcheva, M
    Senillou, A
    Perrot, H
    Furriel, RPM
    Leone, FA
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (17) : 3692 - 3697
  • [6] Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    Cosnier, S
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) : 443 - 456
  • [7] Reversible oligonucleotide immobilisation based on biotinylated polypyrrole film
    Dupont-Filliard, A
    Roget, A
    Livache, T
    Billon, M
    [J]. ANALYTICA CHIMICA ACTA, 2001, 449 (1-2) : 45 - 50
  • [8] Application of conducting polymers to biosensors
    Gerard, M
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) : 345 - 359
  • [9] Preparation of spatially ordered multilayer thin films of antibody and their binding properties
    Hoshi, T
    Saiki, H
    Anzai, JI
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) : 623 - 628
  • [10] Elaboration and characterization of spatially controlled assemblies of complementary polyphenol oxidase-alkaline phosphatase activities on electrodes
    Mousty, C
    Bergamasco, JL
    Wessel, R
    Perrot, H
    Cosnier, S
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (13) : 2890 - 2897