A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method

被引:10
作者
Sono-Koree, N. K. [1 ]
Crist, R. A. [1 ]
Frank, E. L. [1 ,2 ]
Rodgers, G. M. [1 ,2 ,3 ]
Smock, K. J. [1 ,2 ]
机构
[1] Inst Clin & Expt Pathol, ARUP Labs, Salt Lake City, UT USA
[2] Univ Utah, Hlth Sci Ctr, Dept Pathol, Salt Lake City, UT 84108 USA
[3] Univ Utah, Hlth Sci Ctr, Dept Internal Med, Salt Lake City, UT 84108 USA
关键词
Heparin-induced thrombocytopenia; serotonin release assay; high-performance liquid chromatography; platelets; laboratory testing; HEPARIN-INDUCED THROMBOCYTOPENIA; OPTICAL-DENSITY; THROMBOSIS; DIAGNOSIS; ANTIBODIES; PLATELETS; HIT; OPINION; PLASMA; BLOOD;
D O I
10.1111/ijlh.12442
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionThe serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. MethodsWe validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. ResultsSerum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of <6 (% release) for positive, weak positive, and negative serum pools. Stability studies demonstrated stability after two freeze-thaw cycles or up to a week of refrigeration. ConclusionThe HPLC-SRA has robust performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity.
引用
收藏
页码:72 / 80
页数:9
相关论文
共 32 条
[1]   Higher optical density of an antigen assay predicts thrombosis in patients with heparin-induced thrombocytopenia [J].
Altuntas, Fevzi ;
Matevosyan, Karen ;
Burner, James ;
Shen, Yu-Min ;
Sarode, Ravindra .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2008, 80 (05) :429-435
[2]   Pathogenicity of IgA and/or IgM antibodies to heparin-PF4 complexes in patients with heparin-induced thrombocytopenia [J].
Amiral, J ;
Wolf, M ;
Fischer, AM ;
BoyerNeumann, C ;
Vissac, AM ;
Meyer, D .
BRITISH JOURNAL OF HAEMATOLOGY, 1996, 92 (04) :954-959
[3]   DETERMINATION OF SEROTONIN IN WHOLE-BLOOD, PLATELET-RICH PLASMA, PLATELET-POOR PLASMA AND PLASMA ULTRAFILTRATE [J].
ANDERSON, GM ;
FEIBEL, FC ;
COHEN, DJ .
LIFE SCIENCES, 1987, 40 (11) :1063-1070
[4]   PLATELET DENSE GRANULE RELEASE REACTION MONITORED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FLUOROMETRIC-DETERMINATION OF ENDOGENOUS SEROTONIN [J].
ANDERSON, GM ;
HALL, LM ;
YANG, JX ;
COHEN, DJ .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (01) :64-67
[5]   Human platelet IgG Fc receptor FcRIIA in immunity and thrombosis [J].
Arman, M. ;
Krauel, K. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (06) :893-908
[6]   The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion [J].
Cuker, A. ;
Arepally, G. ;
Crowther, M. A. ;
Rice, L. ;
Datko, F. ;
Hook, K. ;
Propert, K. J. ;
Kuter, D. J. ;
Ortel, T. L. ;
Konkle, B. A. ;
Cines, D. B. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (12) :2642-2650
[7]   Predictive value of the 4Ts scoring system for heparin-induced thrombocytopenia: a systematic review and meta-analysis [J].
Cuker, Adam ;
Gimotty, Phyllis A. ;
Crowther, Mark A. ;
Warkentin, Theodore E. .
BLOOD, 2012, 120 (20) :4160-4167
[8]   Activation of platelets by sera containing IgG1 heparin-dependent antibodies: An explanation for the predominance of the Fc gamma RIIa ''low responder'' (his(131)) gene in patients with heparin-induced thrombocytopenia [J].
Denomme, GA ;
Warkentin, TE ;
Horsewood, P ;
Sheppard, JAI ;
Warner, MN ;
Kelton, JG .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1997, 130 (03) :278-284
[9]   Determination of serotonin release from platelets by HPLC and ELISA in the diagnosis of heparin-induced thrombocytopenia:: comparison with reference method by [14C]-serotonin release assay [J].
Fouassier, M ;
Bourgerette, E ;
Libert, F ;
Pouplard, C ;
Marques-Verdier, A .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (05) :1136-1139
[10]   Flow cytometry detection of serotonin content and release in resting and activated platelets [J].
Gobbi, G ;
Mirandola, P ;
Tazzari, PL ;
Ricci, F ;
Caimi, L ;
Cacchioli, A ;
Papa, S ;
Conte, R ;
Vitale, M .
BRITISH JOURNAL OF HAEMATOLOGY, 2003, 121 (06) :892-896