PERFORMANCES OF ONE-DIMENSIONAL SONOMYOGRAPHY AND SURFACE ELECTROMYOGRAPHY IN TRACKING GUIDED PATTERNS OF WRIST EXTENSION

被引:39
作者
Guo, Jing-Yi [1 ]
Zheng, Yong-Ping [1 ]
Huang, Qing-Hua [1 ]
Chen, Xin [1 ]
He, Jun-Feng [1 ]
Chan, Helen Lai-Wa [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Appl Phys, Kowloon, Hong Kong, Peoples R China
关键词
Ultrasound; Sonomyography; SMG; Electromyography; EMG; Muscle; Prosthetic control; HUMAN SKELETAL-MUSCLE; FOREARM MUSCLES; EMG; THICKNESS; SIGNAL; ARCHITECTURE; CONTRACTION; FREQUENCY; BEHAVIOR; SYSTEM;
D O I
10.1016/j.ultrasmedbio.2008.11.017
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Electromyography (EMG) and ultrasonography have been widely used for skeletal muscle assessment. Recently, it has been demonstrated that the muscle thickness change collected by ultrasound during contraction, namely sonomyography (SMG), can also be used for assessment of muscles and has the potential for prosthetic control. In this study, the performances of one-dimensional sonomyography (1D SMG) and surface EMG (SEMG) signal in tracking the guided patterns of wrist extension were evaluated and compared, and the potential of 1D SMG for skeletal muscle assessment and prosthetic control was investigated. Sixteen adult normal subjects including eight males and eight females participated in the experiment. The subject was instructed to perform the wrist extension under the guidance of displayed sinusoidal, square and triangular waveforms at movement rates of 20, 30, 50 cycles per min. SMG and SEMG root mean squares (RMS) were collected from the extensor carpi radialis, respectively, and their RMS errors in relation to the guiding signals were calculated and compared. It was found that the mean RMS tracking errors of SMG tinder different movement rates were 18.9% +/- 2.6% (mean +/- SD), 18.3% +/- 4.5%, and 17.0% +/- 3.4% for sinusoidal, square and triangular guiding waveforms, while the corresponding values for SEMG were 30.3% +/- 0.4%, 29.0% +/- 2.7% and 24.7% +/- 0.7%, respectively. Paired t test showed that the RMS errors of SMG tracking were significantly smaller than those of SEMG. Significant differences in RMS tracking errors of SMG among the three movement rates (p < 0.01) for all the guiding waveforms were also observed using one-way analysis of variance (ANOVA). The results suggest that SMG signal, based on further improvement, has great potential to be an alternative method to SEMG to evaluate muscle function and control prostheses. (E-mail: ypzheng@ieee.org) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:894 / 902
页数:9
相关论文
共 47 条
[1]
Abboudi R L, 1999, IEEE Trans Rehabil Eng, V7, P121, DOI 10.1109/86.769401
[2]
Time-frequency analysis of SEMG - With special consideration to the interelectrode spacing [J].
Alemu, M ;
Kumar, DK ;
Bradley, A .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2003, 11 (04) :341-345
[3]
Quadriceps EMG/force relationship in knee extension and leg press [J].
Alkner, BA ;
Tesch, PA ;
Berg, HE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (02) :459-463
[4]
ALMSTROM C, 1972, P 3 INT C MED PHYS, V33, P2
[5]
Interindividual variation of physical load in a work task [J].
Balogh, I ;
Hansson, GÅ ;
Ohlsson, K ;
Strömberg, U ;
Skerfving, S .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1999, 25 (01) :57-66
[6]
RECORDING SOUND FROM HUMAN SKELETAL-MUSCLE - TECHNICAL AND PHYSIOLOGICAL-ASPECTS [J].
BOLTON, CF ;
PARKES, A ;
THOMPSON, TR ;
CLARK, MR ;
STERNE, CJ .
MUSCLE & NERVE, 1989, 12 (02) :126-134
[7]
Evaluation of the forearm EMG signal features for the control of a prosthetic hand [J].
Boostani, R ;
Moradi, MH .
PHYSIOLOGICAL MEASUREMENT, 2003, 24 (02) :309-319
[8]
Biomimetic finger control by filtering of distributed forelimb pressures [J].
Curcie, DJ ;
Flint, JA ;
Craelius, W .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2001, 9 (01) :69-75
[9]
De Luca C.J., 2002, Surface Electromyography: Detection and Recording
[10]
The use of surface electromyography in biomechanics [J].
De Luca, CJ .