Real-time three-dimensional electrical impedance imaging

被引:35
作者
Blue, RS
Isaacson, D
Newell, JC
机构
[1] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
[2] Rensselaer Polytech Inst, Dept Math Sci, Troy, NY 12180 USA
关键词
electrical impedance tomography;
D O I
10.1088/0967-3334/21/1/303
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrical impedance tomography is a technology for producing images of internal body structures based upon electrical measurements made from electrodes on the body surface. Typically a single plane of electrodes is used, seeking to reconstruct a cross-section of the body. Yet the majority of image reconstruction algorithms ignore the three-dimensional (3D) characteristics of the current Row in the body. Actually, a substantial amount of current Rows out of the electrode plane, creating distortions in the resulting images. This paper describes a reconstruction algorithm, ToDLeR, for solving a linearized 3D inverse problem in impedance imaging. The algorithm models the body as a homogeneous cylinder and accounts for the 3D current flow in the body by analytically solving for the current Row from one or more layers of electrodes on the surface of the cylinder. The algorithm was implemented on the ACT3 real-time imaging system and data were collected From a 3D test phantom using one, two and four layers of electrodes. By using multiple planes of electrodes, improved accuracy in any particular electrode plane was obtained, with decreased sensitivity to out-of-plane objects. A cylindrical target located vertically more than 8 cm below a single layer of 16 electrodes, and positioned radially midway between the centre and the boundary, produced an image that had 35% of the value obtained when the target was in the electrode plane. By adding an additional layer of 16 electrodes below the first electrode plane, and using 3D current patterns, this artefact was reduced to less than 10% of the peak value. We conclude that the 3D algorithm, used with multiple planes of electrodes, reduces the distortions from out-of-plane structures in the body.
引用
收藏
页码:15 / 26
页数:12
相关论文
共 25 条
[1]  
Blue R. S., 1997, Real-time three-dimensional electrical impedance tomography
[2]  
Burden RL., 1989, NUMERICAL ANAL
[3]  
CALDWELL CA, 1995, THESIS RENSSELAER PO
[4]   DISTINGUISHABILITY IN IMPEDANCE IMAGING [J].
CHENEY, M ;
ISAACSON, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (08) :852-860
[5]  
Cheney M, 1990, Int J Imaging Syst Technol, V2, P66, DOI 10.1002/ima.1850020203
[6]   ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
CHENG, KS ;
ISAACSON, D ;
NEWELL, JC ;
GISSER, DG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) :918-924
[7]   RESOLUTION AND STABILITY ANALYSIS OF AN INVERSE PROBLEM IN ELECTRICAL-IMPEDANCE TOMOGRAPHY - DEPENDENCE ON THE INPUT CURRENT PATTERNS [J].
DOBSON, DC ;
SANTOSA, F .
SIAM JOURNAL ON APPLIED MATHEMATICS, 1994, 54 (06) :1542-1560
[8]   A REAL-TIME ELECTRICAL-IMPEDANCE TOMOGRAPH [J].
EDIC, PM ;
SAULNIER, GJ ;
NEWELL, JC ;
ISAACSON, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (09) :849-859
[9]  
EDIC PM, 1994, THESIS RENSSELAER PO
[10]  
Goble JC., 1990, THESIS RENSSELAER PO