Flow injection based renewable electrochemical sensor system

被引:54
作者
Mayer, M [1 ]
Ruzicka, J [1 ]
机构
[1] UNIV WASHINGTON,DEPT CHEM,SEATTLE,WA 98195
关键词
D O I
10.1021/ac960524a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel class of electrochemical sensors is proposed utilizing electrically conducting beads to form a disposable electrode as well as nonconducting beads to form renewable layers of immobilized enzymes. The concept aimed to prevent fouling, is tested on an amperometric sensor coupled to nonconducting beads with different immobilized oxidases: galactose, lactate, alcohol, or glucose oxidase, the latter two being used to determine alcohol and glucose, respectively, in samples of beer and wine, Glucose oxidase was also immobilized on conducting glassy carbon particles to explore the performance of a biosensor where both enzyme and electrode can be automatically renewed in less than I min, The results confirm that the concept of a flow injection renewable electrochemical sensor (FI-RES) is practical, It provides a novel approach to biosensing, to comparing enzyme activity, to studying enzyme immobilization on different supports, and to voltammetry in general.
引用
收藏
页码:3808 / 3814
页数:7
相关论文
共 23 条
[1]   PULSED AMPEROMETRIC DETECTION OF GLUCOSE IN BIOLOGICAL-FLUIDS AT A SURFACE-MODIFIED GOLD ELECTRODE [J].
BINDRA, DS ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1989, 61 (22) :2566-2570
[2]  
Bingkules Y., 1990, J APPL ELECTROCHEM, V20, P974
[3]   Theoretical and experimental studies of the effect of side reactions in copper deposition from dilute solutions on packed-bed electrodes [J].
Bisang, JM .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1996, 26 (02) :135-142
[4]   FLOW-INJECTION RENEWABLE FIBER OPTIC SENSOR SYSTEM - PRINCIPLE AND VALIDATION ON SPECTROPHOTOMETRY OF CHROMIUM(VI) [J].
EGOROV, O ;
RUZICKA, J .
ANALYST, 1995, 120 (07) :1959-1962
[5]   COMPARISON BETWEEN DIFFERENT INORGANIC SUPPORTS FOR THE IMMOBILIZATION OF AMYLOGLUCOSIDASE AND ALPHA-AMYLASE TO BE USED IN ENZYME REACTORS IN FLOW-INJECTION SYSTEMS .1. HYDROLYSIS OF MALTOSE, MALTOOLIGOSACCHARIDES AND SOLUBLE STARCH [J].
EMNEUS, J ;
GORTON, L .
ANALYTICA CHIMICA ACTA, 1993, 276 (02) :303-318
[6]   CHARACTERIZATION OF INHIBITORS OF ACETYLCHOLINESTERASE BY AN AUTOMATED AMPEROMETRIC FLOW-INJECTION SYSTEM [J].
GUNTHER, A ;
BILITEWSKI, U .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :117-125
[7]   ELECTROANALYTICAL VOLTAMMETRY IN FLOWING SOLUTIONS [J].
JOHNSON, DC ;
WEBER, SG ;
BOND, AM ;
WIGHTMAN, RM ;
SHOUP, RE ;
KRULL, IS .
ANALYTICA CHIMICA ACTA, 1986, 180 :187-250
[8]  
JOHNSON DC, 1986, ANAL CHEM, V58, pR33
[9]   COMPARISON BETWEEN DISPERSION AND PLUG-FLOW MODELS FOR FIXED-BED ENZYME REACTORS [J].
LORTIE, R ;
PELLETIER, D .
AICHE JOURNAL, 1992, 38 (09) :1477-1480
[10]   AMPEROMETRIC DETECTION OF PEROXIDES WITH POLY(ANILINOMETHYLFERROCENE)-MODIFIED ENZYME ELECTRODES [J].
MULCHANDANI, A ;
WANG, CL ;
WEETALL, HH .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :94-100