MR first pass imaging: Quantitative assessment of transmural perfusion and collateral flow

被引:52
作者
JeroschHerold, M [1 ]
Wilke, N [1 ]
机构
[1] UNIV MINNESOTA,CTR MAGNET RESONANCE RES,MINNEAPOLIS,MN 55455
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 1997年 / 13卷 / 03期
关键词
myocardium; MR-heart; perfusion-myocardium; blood supply magnetic resonance; contrast enhancement;
D O I
10.1023/A:1005784820067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Recent advances with fast switching gradient coils, and the optimization of magnetic resonance techniques for multislice imaging have made it possible to apply models of contrast agent transit for the quantification of myocardial perfusion, and determination of the transmural distribution of blood flow. This article summarizes some of these recent developments and presents examples of quantitative, multi-slice myocardial perfusion imaging studies in patients and animal models. Multi-slice, true first pass imaging, with high temporal resolution, and T-1-weighted, arrhythmia insensitive contrast enhancement is used for the quantification of perfusion changes accompanying mild to severe ischemia. The first pass imaging technique and the modeling approach are sufficiently robust for fitting of tissue residue curves corresponding to a wide, physiologically realistic range of myocardial blood flows. In animals this was validated by comparison to blood flow measurements with radiorabeled microspheres as gold standard. It is demonstrated that with the proposed modeling approach one can determine the myocardial perfusion reserve from two consecutive MR first pass measurements under resting and hyperemic conditions. In patients with microvascular dysfunction the MR studies show for the first time that the myocardial perfusion reserve correlates with Doppler flow measurements (linear regression with slope of 1.02 +/- 0.09; r = 0.80). Since perfusion limitations usually begin in the subendocardium as coronary flow is gradually reduced, first pass imaging with the prerequisitie spatial and temporal resolution allows early detection of a mild coronary stenosis.
引用
收藏
页码:205 / 218
页数:14
相关论文
共 53 条
[1]   NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY [J].
ARAUJO, LI ;
LAMMERTSMA, AA ;
RHODES, CG ;
MCFALLS, EO ;
IIDA, H ;
RECHAVIA, E ;
GALASSI, A ;
DESILVA, R ;
JONES, T ;
MASERI, A .
CIRCULATION, 1991, 83 (03) :875-885
[2]   TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[3]   EFFECT OF PERFUSION-PRESSURE DISTAL TO A CORONARY STENOSIS ON TRANSMURAL MYOCARDIAL BLOOD-FLOW [J].
BACHE, RJ ;
SCHWARTZ, JS .
CIRCULATION, 1982, 65 (05) :928-935
[4]  
BASSINGTHWAIGHT.JB, 1993, NUCL CARDIOLOGY STAT, P3
[5]  
Bassingthwaighte J., 1984, HDB PHYSL 2, V4, P549
[6]   NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL FLOW RESERVE IN PATIENTS WITH CORONARY ATHEROSCLEROSIS USING N-13 AMMONIA POSITRON EMISSION TOMOGRAPHY - DETERMINATION OF EXTENT OF ALTERED VASCULAR REACTIVITY [J].
BEANLANDS, RSB ;
MUZIK, O ;
MELON, P ;
SUTOR, R ;
SAWADA, S ;
MULLER, D ;
BONDIE, D ;
HUTCHINS, GD ;
SCHWAIGER, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (06) :1465-1475
[7]  
BURR DJ, 1981, COMPUT VISION GRAPH, V15, P102, DOI 10.1016/0146-664X(81)90072-1
[8]   NONINVASIVE ASSESSMENT OF NO-REFLOW PHENOMENON IN A CANINE MODEL OF REPERFUSED INFARCTION BY CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING [J].
CANET, E ;
REVEL, D ;
SEBBAG, L ;
DELORGERIL, M ;
BALDY, C ;
DELABRE, C ;
AMIEL, M .
AMERICAN HEART JOURNAL, 1995, 130 (05) :949-956
[9]   REGIONAL TRANSIT-TIME ESTIMATION FROM IMAGE RESIDUE CURVES [J].
CLOUGH, AV ;
ALTINAWI, A ;
LINEHAN, JH ;
DAWSON, CA .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (02) :128-143
[10]   DIGITAL SUBTRACTION ANGIOGRAPHIC IMAGING OF CORONARY FLOW RESERVE [J].
CUSMA, JT ;
TOGGART, EJ ;
FOLTS, JD ;
PEPPLER, WW ;
HANGIANDREOU, NJ ;
LEE, CS ;
MISTRETTA, CA .
CIRCULATION, 1987, 75 (02) :461-472