Long term performance of a hand held spirometer

被引:25
作者
Dirksen, A
Madsen, F
Pedersen, OF
Vedel, AM
KokJensen, A
机构
[1] BISPEBJERG HOSP, DEPT PULM MED, DK-2400 COPENHAGEN NV, DENMARK
[2] AARHUS UNIV, DEPT ENVIRONM OCCUPAT MED, DK-8000 AARHUS C, DENMARK
关键词
patient-administered serial spirometry (PASS); hand held turbine spirometer; long term reproducibility; volume and flow calibration;
D O I
10.1136/thx.51.10.973
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background - A study was undertaken to test the long term performance of a small hand held spirometer for self-administered serial spirometric testing. Methods - Thirty turbine pocket spirometers (MicroMedical DiaryCard) were used in a clinical trial on 22 emphysematous patients with severe alpha(1)-antitrypsin deficiency. The spirometers were able to store the date, time, forced expiratory volume in one second (FEV(1)), forced vital capacity (FVC), peak expiratory flow (PEF), and flow-volume loop for each blow. Every four weeks when the patients came for alpha(1)-antitrypsin infusions the performance of their spirometer was checked before and after retrieval of the data from the spirometer. Calibration checks were threefold and included volume calibration with a 1.0 litre and 3.0 litre syringe, and flow calibration with a decompression calibrator. Results - After two years of study the mean number of spirometric recordings performed per spirometer was 693 (range 237-1178), and the mean number of calibration checks was 33 (range 2-57). The coefficient of variation of the calibration signal was 1-2% for syringes and 0.5-1% for the decompression calibrator. The bearings of one turbine exhibited excessive friction after 17 months. None of the other 29 instruments showed drift, and a general drift of all spirometers towards larger or smaller readings could not be shown. However, unforeseen problems in the stability of the calibrating devices were observed. Conclusions - The small hand held turbine spirometers are suitable for long term patient-administered serial spirometric testing. The two year durability is acceptable and the long term reproducibility excellent.
引用
收藏
页码:973 / 976
页数:4
相关论文
共 12 条
[2]  
BJORTUFT O, 1993, EUR RESPIR J, V6, P705
[3]  
BURROWS B, 1983, AM REV RESPIR DIS, V127, pS42
[4]   POCKET-SIZED DEVICE FOR MEASURING FORCED EXPIRATORY VOLUME IN ONE 2ND AND FORCED VITAL CAPACITY [J].
CHOWIENCZYK, PJ ;
LAWSON, CP .
BRITISH MEDICAL JOURNAL, 1982, 285 (6334) :15-17
[5]   DO ASTHMATIC-PATIENTS CORRECTLY RECORD HOME SPIROMETRY MEASUREMENTS [J].
CHOWIENCZYK, PJ ;
PARKIN, DH ;
LAWSON, CP ;
COCHRANE, GM .
BRITISH MEDICAL JOURNAL, 1994, 309 (6969) :1618-1618
[6]  
DIRKSEN A, 1994, AM J RESP CRIT CARE, V149, pA1008
[7]  
DIRKSEN A, 1991, EUR RESPIR REV, V1, P432
[8]   Patient-administered sequential spirometry in healthy volunteers and patients with alpha(1)-antitrypsin deficiency [J].
Madsen, F ;
Ulrik, CS ;
Dirksen, A ;
Hansen, KK ;
Nielsen, NH ;
Frolund, L ;
Viskum, K ;
KokJensen, A .
RESPIRATORY MEDICINE, 1996, 90 (03) :131-138
[9]  
ORULANA BA, 1990, CHEST, V97, P953
[10]  
PEDERSEN OF, 1983, B EUR PHYSIOPATH RES, V19, P515