Simplified model of laser Doppler signals during reactive hyperaemia

被引:18
作者
Humeau, A [1 ]
Saumet, JL
L'Huillier, JP
机构
[1] ESAIP, Grp ISAIP, St Barthelemy, France
[2] CHU Angers, Serv Explorat Vasc, Angers, France
[3] Ecole Natl Super Arts & Metiers, Lab Adv Instrumentat & Robot, Angers, France
关键词
laser Doppler flowmetry; model; reactive hyperaemia;
D O I
10.1007/BF02344693
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Laser Doppler flowmetry (LDF) is a non-invasive method to measure tissue blood flow. During reactive hyperaemia, the LDF signal increases to a peak and then returns to a resting value. A simplified model is developed to explain these variations. The emphasis is on simulating the effects occurring rather than on trying to mimic the anatomical structure of the microcirculation. A single blood vessel is therefore analysed. The increasing value of blood velocity is studied, and vasodilatation as well as vasoconstriction are taken into account. The model parameters are calculated using wavelets. For a 2-min occlusion on a healthy subject, the radius of the vessel is initially 15 mu m, increasing to 24.6 mu m at the peak, reached 14s after the release of the occlusion. The model shows that the high value of the LDF signal during the initial phase of reactive hyperaemia is produced by an increasing number of erythrocytes in a cross-section, due to vasodilatation rather than an increase in moving blood cell velocities. Moreover, the rapidity of the vasodilatation and vasoconstriction effects determine the rapidity of the signal variations. The paper aims to give a basic solution to develop a numerical model.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 30 条
[1]  
ABBOT NC, 1993, INT J MICROCIRC, V12, P89
[2]  
[Anonymous], J MATH PURES APPL
[3]  
BERNE RM, 1996, PRINCIPLES PHYSL, P219
[4]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[5]  
Bonner R. F., 1990, Principles of laser-Doppler Flowmetry, P17, DOI [10.1007/978-1-4757-2083-9_2, DOI 10.1007/978-1-4757-2083-9_2]
[6]  
COLANTUONI A, 1993, INT J MICROCIRC, V13, P125
[7]   MICROVASCULAR VASOMOTION - ORIGIN OF LASER-DOPPLER FLUX MOTION [J].
COLANTUONI, A ;
BERTUGLIA, S ;
INTAGLIETTA, M .
INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1994, 14 (03) :151-158
[8]  
COLANTUONI A, 1984, AM J PHYSIOL, V246, P508
[9]   OBSERVATIONS OF A LASER DOPPLER FLOWMETER OUTPUT MADE USING A CALIBRATION STANDARD [J].
FAIRS, SLE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (04) :404-406
[10]  
GAEHTGENS P, 1980, BLOOD CELLS, V6, P799