Improving sensitivity for CE-ICP-MS using multicapillary parallel separation

被引:40
作者
Majidi, V
Qvarnström, J
Tu, Q
Frech, W
Thomassen, Y
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Umea Univ, Dept Chem Analyt Chem, S-90187 Umea, Sweden
[3] Natl Inst Occupat Hlth, N-0033 Oslo, Norway
关键词
D O I
10.1039/a906100b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multicapillary, capillary electrophoresis inductively coupled plasma mass spectrometry interface is described. This interface allows for higher sample loading to improve the overall sensitivity and analyte detection limits without sacrificing the separation efficiencies. The results obtained with this parallel system are presented for a cross flow nebulizer. A comparison of single capillary electrophoresis for both DIHEN and cross flow nebulizers is presented.
引用
收藏
页码:1933 / 1935
页数:3
相关论文
共 13 条
[1]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[2]   Investigation of selenium speciation in in vitro gastrointestinal extracts of cooked cod by high-performance liquid chromatography inductively coupled plasma mass spectrometry and electrospray mass spectrometry [J].
Crews, HM ;
Clarke, PA ;
Lewis, DJ ;
Owen, LM ;
Strutt, PR ;
Izquierdo, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1177-1182
[3]  
Donais MK, 1998, SPECTROSCOPY, V13, P30
[4]   An evaluation of ultrasonic nebulizers as interfaces for capillary electrophoresis of inorganic anions and cations with inductively coupled plasma mass spectrometric detection [J].
Kirlew, PW ;
Castillano, MTM ;
Caruso, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) :221-237
[5]   Investigation of a modified oscillating capillary nebulizer design as an interface for CE-ICP-MS [J].
Kirlew, PW ;
Caruso, JA .
APPLIED SPECTROSCOPY, 1998, 52 (05) :770-772
[6]   Elemental speciation and coupled techniques [J].
Lobinski, R .
APPLIED SPECTROSCOPY, 1997, 51 (07) :A260-A278
[7]   INTERFACE FOR CAPILLARY ELECTROPHORESIS AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
LU, QH ;
BIRD, SM ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2949-2956
[8]   Potential sources of error in capillary electrophoresis inductively coupled plasma mass spectrometry for chemical speciation [J].
Majidi, V ;
Miller-Ihli, NJ .
ANALYST, 1998, 123 (05) :809-813
[9]   Two simple interface designs for capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Majidi, V ;
Miller-Ihli, NJ .
ANALYST, 1998, 123 (05) :803-808
[10]  
OLESIK JW, 1997, ANAL CHEM, V67, P1