Chromatographic determination of flumequine in food samples by post-column derivatisation with terbium(III)

被引:23
作者
Rodriguez-Diaz, R. C. [1 ]
Fernandez-Romero, J. M. [1 ]
Aguilar-Caballos, M. P. [1 ]
Gomez-Hens, A. [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
flumequine; terbium(III); fluorescence and time-resolved detection; liquid chromatography; food samples;
D O I
10.1016/j.aca.2006.06.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential usefulness of terbium(III) as reagent for the luminescent determination of flumequine residues in food samples has been studied using both fluorescence (FL) and time-resolved (TR) modes and both batch (B) and integrated liquid chromatography (LC)/derivatisation approaches. The system was optimised in each instance to establish the analytical features of the four methods. The dynamic ranges of the calibration graphs, obtained with standard solutions of flumequine, were (ng mL(-1)): B-FL 0.18-600; B-TR 2.4-150; LC-FL 3.7-1000 and LC-TR 52-3000. The detection limits were also obtained giving the following values (ng mL(-1)): B-FL 0.055; B-TR 0.7; LC-FL 1.1 and LC-TR 15. The precision, expressed as the percentage of relative standard deviation, was equal or lower than 5.1% in all instances. The LC methods, which avoid the interference of other quinolone antibiotics, were applied to the analysis of chicken muscle and liver, and whole milk samples. The sample pre-treatment only consisted of a deproteinisation step. The validation procedure for the analysis of samples was carried out using EC recommendations, and the decision limit and detection capability were calculated. The recoveries obtained ranged from 95.0% to 103.8%. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 226
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 2002, Off. J. Eur. Comm, VL221, P8
[2]  
*AOAC, 11995 AOAC PVM
[3]   Determination of fluoroquinolones in chicken tissues by LC-coupled electrospray ionisation and atmospheric pressure chemical ionisation [J].
Bailac, S ;
Barrón, D ;
Sanz-Nebot, V ;
Barbosa, J .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (01) :131-136
[4]   Occurrence and diversity of tetracycline resistance genes in lagoons and groundwater underlying two swine production facilities [J].
Chee-Sanford, JC ;
Aminov, RI ;
Krapac, IJ ;
Garrigues-Jeanjean, N ;
Mackie, RI .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (04) :1494-1502
[5]   Determination of flumequine and 7-hydroxyflumequine in plasma of sheep by high-performance liquid chromatography [J].
Delmas, JM ;
Chapel, AM ;
Sanders, P .
JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2) :263-268
[6]   Terbium-sensitized luminescence:: a selective and versatile analytical approach [J].
Gómez-Hens, A ;
Aguilar-Caballos, MP .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (02) :131-141
[7]   Routine determination of flumequine in kidney tissue of pig using automated liquid chromatography [J].
Guyonnet, J ;
Pacaud, M ;
Richard, M ;
Doisi, A ;
Spavone, F ;
Hellings, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 679 (1-2) :177-184
[8]   Fast-scanning fluorescence spectroscopy as a detection system in liquid chromatography for confirmatory analysis of flumequine and oxolinic acid [J].
Hernández-Arteseros, JA ;
Beltrán, JL ;
Compañó, R ;
Prat, MD .
JOURNAL OF CHROMATOGRAPHY A, 2002, 942 (1-2) :275-281
[9]   Determination and on-line clean-up of (fluoro)quinolones in bovine milk using column-switching liquid chromatography fluorescence detection [J].
Ho, C ;
Sin, DWM ;
Tang, HPO ;
Chung, LPK ;
Siu, SMP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :123-131
[10]  
*JOINT FAO WHO EXP, 2004, TECHN REP SER, V925