Does contrast echocardiography with Optison induce myocardial necrosis in humans?

被引:33
作者
Borges, AC
Walde, T
Reibis, RK
Grohmann, A
Ziebig, R
Rutsch, W
Schimke, I
Baumann, G
机构
[1] Humboldt Univ, Klinikum Charite, Med Kardiol Pneumol & Angiol, Berlin, Germany
[2] Humboldt Univ, Klinikum Charite, Inst Lab Med, Berlin, Germany
关键词
D O I
10.1067/mje.2002.121833
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial contrast echocardiography is a promising diagnostic tool for detecting microvascular integrity. Multiple experimental laboratories have shown that diagnostic combined microbubble contrast and ultrasound exposure can cause vessel rupture and myocardial damage in laboratory animals. This study investigated the phenomenon of contrast ultrasonically induced myocardial damage in human beings. Twenty consecutive patients (mean age of 60 12 years, 14 men) underwent contrast echocardiography with intravenous Optison using a mechanical index of at least 1.4 (Vivid Five System (GE, Vingmed Ultrasound, Horton, Norway). Creatine kinase (CK), creatine kinase-isoenzyme MB (CK-MB); CK-MB mass, myoglobin, and troponin I were measured before and 2, 4, 8, and 24 hours after contrast echocardiography. There was no significant correlation concerning the response to contrast echocardiography for any pair of parameters at any time after the intervention. Only in 2 patients were there higher values for troponin I before and after contrast echocardiography without an increase of myoglobin, CK, or CK-MB mass and activity. These values were therefore interpreted as false positive because of renal failure and severe heart failure. The use of contrast echocardiography is without demonstrated risk of myocardial damage even in patients with different cardiologic entities.
引用
收藏
页码:1080 / 1086
页数:7
相关论文
共 23 条
[1]   CARDIAC TROPONIN-I - A MARKER WITH HIGH SPECIFICITY FOR CARDIAC INJURY [J].
ADAMS, JE ;
BODOR, GS ;
DAVILAROMAN, VG ;
DELMEZ, JA ;
APPLE, FS ;
LADENSON, JH ;
JAFFE, AS .
CIRCULATION, 1993, 88 (01) :101-106
[2]  
APFEL RE, 1982, BRIT J CANCER, V45, P140
[3]   Prognostic value of serum cardiac troponin I and T in chronic dialysis patients: A 1-year outcomes analysis [J].
Apple, FS ;
Sharkey, SW ;
Hoeft, P ;
Skeate, R ;
Voss, E ;
Dahlmeier, BA ;
Preese, LM .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 29 (03) :399-403
[4]   Destruction of contrast microbubbles by ultrasound - Effects on myocardial function, coronary perfusion pressure, and microvascular integrity [J].
Ay, T ;
Havaux, X ;
Van Camp, G ;
Campanelli, B ;
Gisellu, G ;
Pasquet, A ;
Denef, JF ;
Melin, JA ;
Vanoverschelde, JLJ .
CIRCULATION, 2001, 104 (04) :461-466
[5]  
DALECKI D, 1996, ULTRASOUND MED BIOL, V23, P917
[6]   Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress comparison with 99mTc-Sestamibi SPECT imaging [J].
Heinle, SK ;
Noblin, J ;
Goree-Best, P ;
Mello, A ;
Ravad, G ;
Mull, S ;
Mammen, P ;
Grayburn, PA .
CIRCULATION, 2000, 102 (01) :55-60
[7]   Testing the wrong hypothesis: The failure to recognize the limitations of troponin assays [J].
Jaffe, AS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (04) :999-1001
[8]  
Kaul S, 1997, CIRCULATION, V96, P3745
[9]  
Lafitte S, 2001, J AM SOC ECHOCARDIOG, V14, P1010
[10]   Assessment of myocardial reperfusion by intravenous myocardial contrast echocardiography and coronary flow reserve after primary percutaneous transluminal coronary angiography in patients with acute myocardial infarction [J].
Lepper, W ;
Hoffmann, R ;
Kamp, O ;
Franke, A ;
de Cock, CC ;
Kühl, HP ;
Sieswerda, GT ;
vom Dahl, J ;
Janssens, U ;
Voci, P ;
Visser, CA ;
Hanrath, P .
CIRCULATION, 2000, 101 (20) :2368-2374