Recent developments in SPME for on-site analysis and monitoring

被引:168
作者
Ouyang, Gangfeng
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Sun Yat Sen Univ, Sch Chem & Chem Engn, Guangzhou 510275, Peoples R China
关键词
calibration; environmental analysis; environmental monitoring; on-site; quantification; solid-phase microextraction; SPME;
D O I
10.1016/j.trac.2006.05.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The following review focuses on recent developments in solid-phase microextraction (SPME) for on-site analysis and monitoring of environmental pollutants, including calibration methods and sampling devices. The review emphasizes calibration methods, including traditional, equilibrium extraction and several diffusion-based. We also discuss the characteristics of these calibration methods. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:692 / 703
页数:12
相关论文
共 85 条
[1]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[2]   Headspace solid phase microextraction. Dynamics and quantitative analysis before reaching a partition equilibrium [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3260-3266
[3]  
Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
[4]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[5]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[6]   Applications of solid-phase microextraction to chemical analysis of live biological samples [J].
Augusto, F ;
Valente, ALP .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (6-7) :428-438
[7]   Design and validation of portable SPME devices for rapid field air sampling and diffusion based calibration [J].
Augusto, F ;
Koziel, J ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :481-486
[8]   A review on solid phase micro extraction-high performance liquid chromatography (SPME-HPLC) analysis of pesticides [J].
Aulakh, JS ;
Malik, AK ;
Kaur, V ;
Schmitt-Kopplin, P .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2005, 35 (01) :71-85
[9]   Development of a personal isocyanate sampler based on DBA derivatization on solid-phase microextraction fibers [J].
Batlle, R ;
Colmsjö, A ;
Nilsson, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (04) :514-518
[10]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245