Incidence of lightspeed separation and the potential for bypassing

被引:33
作者
RamirezSalomon, M [1 ]
SolerBientz, R [1 ]
delaGarzaGonzalez, R [1 ]
PalaciosGarza, CM [1 ]
机构
[1] INST POLITECN NACL,CTR INVEST & ESTUDIOS AVANZADOS,DEPT PHYS,MEXICO CITY 07738,DF,MEXICO
关键词
D O I
10.1016/S0099-2399(06)81128-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
It is important for endodontic instruments to have a low fracture rate. If a fracture does occur, it would be desirable to have the ability to bypass the broken segment and complete the root canal treatment. One hundred sixty-two root canals in 52 maxillary and mandibular first molars were cleaned and shaped with Lightspeed instruments by three endodontists in their private practices. The canals were instrumented using the technique recommended by the manufacturer. All canals were instrumented to at least a size 45 at the working length. Six instruments separated during treatment. All six had been used more times than recommended by the manufacturer. Five of the six were easily bypassed and treatment completed.
引用
收藏
页码:586 / 587
页数:2
相关论文
共 19 条
[1]   THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL [J].
ABOURASS, M ;
FRANK, AL ;
GLICK, DH .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) :792-794
[2]   TORSIONAL AND STIFFNESS PROPERTIES OF CANAL MASTER-U STAINLESS-STEEL AND NITINOL INSTRUMENTS [J].
CAMPS, J ;
PERTOT, WJ .
JOURNAL OF ENDODONTICS, 1994, 20 (08) :395-398
[3]   THE EFFECT OF DIFFERENT FILES ON THE PREPARATION SHAPE OF SEVERELY CURVED CANALS [J].
ELDEEB, ME ;
BORAAS, JC .
INTERNATIONAL ENDODONTIC JOURNAL, 1985, 18 (01) :1-7
[4]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[5]   INSTRUMENTATION OF ROOT CANALS IN MOLAR USING THE STEP-DOWN TECHNIQUE [J].
GOERIG, AC ;
MICHELICH, RJ ;
SCHULTZ, HH .
JOURNAL OF ENDODONTICS, 1982, 8 (12) :550-554
[6]  
GUILLES JA, 1990, J ENDODONT, V16, P561
[7]  
INGLE J I, 1961, Oral Surg Oral Med Oral Pathol, V14, P83, DOI 10.1016/0030-4220(61)90477-7
[8]   THE EFFECTS OF CANAL MASTER, FLEX-R, AND K-FLEX INSTRUMENTATION ON ROOT-CANAL CONFIGURATION [J].
LESEBERG, DA ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1991, 17 (02) :59-65
[9]   TORSIONAL PROPERTIES OF THE CANAL MASTER INSTRUMENT [J].
MASSA, GR ;
NICHOLLS, JI ;
HARRINGTON, GW .
JOURNAL OF ENDODONTICS, 1992, 18 (05) :222-227
[10]   CANAL MASTER INSTRUMENTATION - AN INVITRO STUDY OF SEPARATION FREQUENCY [J].
MOUNCE, RE ;
NAKAMUTA, H ;
LOVEJOY, C .
JOURNAL OF ENDODONTICS, 1993, 19 (01) :1-3