Does rating of perceived exertion result in target exercise intensity during interval training in cardiac rehabilitation? A study of the Borg scale versus a heart rate monitor

被引:56
作者
Aamot, Inger-Lise [1 ,2 ]
Forbord, Siv Hege [2 ]
Karlsen, Trine [1 ,3 ]
Stoylen, Asbjorn [3 ,4 ]
机构
[1] Norwegian Univ Sci & Technol, Fac Med, KG Jebsen Ctr Exercise Med, Trondheim, Norway
[2] St Olavs Univ Hosp, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, Trondheim, Norway
[4] St Olavs Univ Hosp, Dept Cardiol, Trondheim, Norway
关键词
Aerobic exercise; Target exercise intensity; Secondary prevention; Heart rate; Coronary artery disease; STATISTICAL-METHODS; ASSESSING AGREEMENT; OXYGEN-UPTAKE; PRESCRIPTION; STATEMENT; VALIDITY;
D O I
10.1016/j.jsams.2013.07.019
中图分类号
G8 [体育];
学科分类号
040301 [体育人文社会学];
摘要
Objectives: To assess whether rating of perceived exertion using the Borg 6-20 scale is a valid method for achieving target exercise intensity during high-intensity interval training in cardiac rehabilitation. Design: A single-group cross-over design. Methods: Ten participants (56 (6.5) years) who were enrolled in a high-intensity interval training cardiac rehabilitation program were recruited. A target exercise intensity of Borg 17 (very hard) was used for exercise intensity guidance in the initial four exercise sessions that took place before a cardiopulmonary exercise test, as in usual care rehabilitation. The heart rate was recorded and blinded to the participants. After performing the test, the participants were then instructed using heart rate monitors openly for exercise guidance in four subsequent exercise sessions, at an intensity corresponding to 85-95% of peak heart rate. Results: The mean exercise intensity during high-intensity bouts was 82% (6%) of peak heart rate for the rating of perceived exertion and 85% (6%) using heart rate monitors (p = 0.005). Bland-Altman limits of agreement analysis with a mean bias showed a bias of 2.97 (-2.08, 8.02) percentage points for the two methods. Exercise intensity was highly repeatable with intra-class correlations of 0.95(95% CI 0.86-0.99, p < 0.001) and 0.96(95% CI 0.88-0.99, p < 0.001) in the exercise sessions using rating of perceived exertion and percentage of peak heart rate for intensity control, respectively. Conclusions: Rating of perceived exertion results in an exercise intensity below target during high-intensity interval training bouts in cardiac rehabilitation. Heart rate monitoring should be used for accurate intensity guidance. (C) 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:541 / 545
页数:5
相关论文
共 30 条
[1]
Aamot I, 2013, EUR J PREV CARD 0423
[2]
Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[5]
Reproducibility of ratings of perceived exertion soon after myocardial infarction: responses in the stress-testing clinic and the rehabilitation gymnasium [J].
Buckley, John P. ;
Sim, Julius ;
Eston, Roger G. .
ERGONOMICS, 2009, 52 (04) :421-427
[6]
Chaloupka Vaclav, 2005, J Cardiopulm Rehabil, V25, P361, DOI 10.1097/00008483-200511000-00009
[7]
Criterion-related validity of the Borg ratings of perceived exertion scale in healthy individuals: a meta-analysis [J].
Chen, MJ ;
Fan, XT ;
Moe, ST .
JOURNAL OF SPORTS SCIENCES, 2002, 20 (11) :873-899
[8]
The use of ratings of perceived exertion for exercise prescription in patients receiving beta-blocker therapy [J].
Eston, R ;
Connolly, D .
SPORTS MEDICINE, 1996, 21 (03) :176-190
[9]
Eston R G, 1988, Br J Sports Med, V22, P153
[10]
The validity of predicting maximal oxygen uptake from a perceptually-regulated graded exercise test [J].
Eston, RG ;
Lamb, KL ;
Parfitt, G ;
King, N .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2005, 94 (03) :221-227