Characterization of focal liver lesions with contrast specific US modes and a sulfur hexafluoride-filled microbubble contrast agent: Diagnostic performance and confidence

被引:396
作者
Quaia, E
Calliada, F
Bertolotto, M
Rossi, S
Garioni, L
Rosa, L
Pozzi-Mucelli, R
机构
[1] Univ Trieste, Cattinara Hosp, Dept Radiol, I-34149 Trieste, Italy
[2] Univ Pavia, San Matteo Hosp, Dept Radiol, Pavia, Italy
[3] Univ Pavia, San Matteo Hosp, Operat Unit Intervent Ultrasound, Pavia, Italy
关键词
liver neoplasms; diagnosis; US; microbubbles; ultrasound (US); contrast media;
D O I
10.1148/radiol.2322031401
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess whether characterization of solid focal liver lesions could be improved by using ultrasonographic (US) contrast-specific modes after sulfur hexafluoride-filled microbubble contrast agent injection, as compared with lesion characterization achieved with preliminary baseline US. MATERIALS AND METHODS: Four hundred fifty-two solid focal hepatic lesions that were considered indeterminate at baseline gray-scale and color Doppler US were examined after microbubble contrast agent injection performed by using low-acoustic-power contrast-specific modes during the arterial (10-40 seconds after injection), portal venous (50-90 seconds after injection), and late (100-300 seconds after injection) phases. Two readers independently and retrospectively reviewed baseline and contrast material-enhanced US scans and classified each depicted lesion as malignant or benign according to standard diagnostic criteria. Sensitivity, specificity, accuracy, and positive and negative predictive values and areas under the receiver operating characteristic curve (A(z)) were calculated by considering histologic analysis (317 patients) or contrast-enhanced helical computed tomography followed by serial US 3-6 months apart (1135 patients) as the reference standards. RESULTS: Different contrast enhancement patterns were observed according to lesion characteristics. During the late phase, benign lesions were predominantly hyper- or isoechoic relative to the adjacent liver parenchyma, whereas malignant lesions were predominantly hypoechoic. Review of the contrast-enhanced US scans after baseline image review yielded significantly improved diagnostic performance (P < .05). Overall diagnostic accuracy was 49% before versus 85% after review of the contrast-enhanced scan for reader 1 and 51% before versus 88% after review of the contrast-enhanced scan for reader 2. Diagnostic confidence-that is, the A(z)-was 0.820 before versus 0.968 after review of the contrast-enhanced scan for reader 1 and 0.831 before versus 0.978 after review of the contrast-enhanced scan for reader 2. CONCLUSION: The use of contrast-specific modes with a sulfur hexafluoride contrast agent led to improved characterization of solid focal liver lesions. (C) RSNA, 2004.
引用
收藏
页码:420 / 430
页数:11
相关论文
共 37 条
[1]  
BECK JR, 1986, ARCH PATHOL LAB MED, V110, P13
[2]   Characterization of unifocal liver lesions with pulse inversion harmonic imaging after Levovist injection: preliminary results [J].
Bertolotto, M ;
Dalla Palma, L ;
Quaia, E ;
Locatelli, M .
EUROPEAN RADIOLOGY, 2000, 10 (09) :1369-1376
[3]   SURGICAL ANATOMY AND ANATOMICAL SURGERY OF THE LIVER [J].
BISMUTH, H .
WORLD JOURNAL OF SURGERY, 1982, 6 (01) :3-9
[4]   Stimulated acoustic emission in liver parenchyma with Levovist [J].
Blomley, M ;
Albrecht, T ;
Cosgrove, D ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, R .
LANCET, 1998, 351 (9102) :568-568
[5]   Do different types of liver lesions differ in their uptake of the microbubble contrast agent SHU 508A in the late liver phase? Early experience [J].
Blomley, MJK ;
Sidhu, PS ;
Cosgrove, DO ;
Albrecht, T ;
Harvey, CJ ;
Heckemann, RA ;
Butler-Barnes, J ;
Eckersley, RJ ;
Basilico, R .
RADIOLOGY, 2001, 220 (03) :661-667
[6]   Focal nodular hyperplasia: CT findings with emphasis on multiphasic helical CT in 78 patients [J].
Brancatelli, G ;
Federle, MP ;
Grazioli, L ;
Blachar, A ;
Peterson, MS ;
Thaete, L .
RADIOLOGY, 2001, 219 (01) :61-68
[7]   Pulse inversion imaging of liver blood flow - Improved method for characterizing focal masses with microbubble contrast [J].
Burns, PN ;
Wilson, SR ;
Simpson, DH .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :58-71
[8]  
Campbell MJ, 1999, MED STAT COMMONSENSE, P85
[9]   Ultrasound contrast agents:: properties, principles of action, tolerance, and artifacts [J].
Correas, JM ;
Bridal, L ;
Lesavre, A ;
Méjean, A ;
Claudon, M ;
Hélénon, O .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1316-1328
[10]   Infusion versus bolus of an ultrasound contrast agent - In vivo dose-response measurements of BR1 [J].
Correas, JM ;
Burns, PN ;
Lai, XM ;
Qi, XL .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :72-79