Latex allergy: The perspective from the surgical suite

被引:11
作者
Elliott, BA [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Anesthesiol, Mayo Med Sch, Rochester, MN 55905 USA
关键词
latex allergy; surgical gloves; occupational allergy; health care workers;
D O I
10.1067/mai.2002.125594
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Latex allergy in the perioperative setting presents unique challenges to the health care system. Specific needs of the latex-sensitive patient are paramount, but consideration must also include the impact on health care workers vis-a-vis latex sensitization, environmental allergen control, and barrier protection against blood-borne pathogens. It has been well documented that the greatest source of latex aeroallergen in the surgical setting is latex gloves (both sterile and nonsterile). Levels of latex aeroallergen correlate strongly with use of high-allergen and powdered gloves, total number of gloves used, and the hours of activity in a given environment. A significant reduction in aeroallergen (>10-fold) can be achieved by switching to low-allergen gloves. Ready availability of and encouragement to use nonlatex alternatives when appropriate can further reduce exposure to latex allergens. Since 1998, the Food and Drug Administration has required all medical devices (or their packaging) that contain natural rubber latex to be so labeled. In addition, industry has responded with a host of latex-free products for use in patient care. This has helped eliminate a great deal of confusion about which products are safe for use with latex-sensitive individuals. However, despite significant efforts to educate the public and the health care industry regarding latex allergies, considerable misinformation persists. Provision of a completely latex-free environment in most surgical suites may be unrealistic, but every effort should be made to minimize the unnecessary exposure of patients and health care workers to latex allergens in this high-risk arena.
引用
收藏
页码:S117 / S120
页数:4
相关论文
共 50 条
  • [1] Bernardini R, 1999, CLIN EXP ALLERGY, V29, P681
  • [2] The implications of latex allergy in healthcare settings
    Bowyer, RVSL
    [J]. JOURNAL OF CLINICAL NURSING, 1999, 8 (02) : 139 - 143
  • [3] CONTACT URTICARIA AND RHINITIS FROM LATEX SURGICAL GLOVES
    CARRILLO, T
    CUEVAS, M
    MUNOZ, T
    HINOJOSA, M
    MONEO, I
    [J]. CONTACT DERMATITIS, 1986, 15 (02) : 69 - 72
  • [4] OCCUPATIONAL LATEX EXPOSURE - CHARACTERISTICS OF CONTACT AND SYSTEMIC REACTIONS IN 47 WORKERS
    CHAROUS, BL
    HAMILTON, RG
    YUNGINGER, JW
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 94 (01) : 12 - 18
  • [5] DeSwert LFA, 1997, CLIN EXP ALLERGY, V27, P1067
  • [6] SEVERE INTRAOPERATIVE ANAPHYLAXIS TO SURGICAL GLOVES - LATEX ALLERGY, AN UNFAMILIAR CONDITION
    GERBER, AC
    JORG, W
    ZBINDEN, S
    SEGER, RA
    DANGEL, PH
    [J]. ANESTHESIOLOGY, 1989, 71 (05) : 800 - 802
  • [7] PERMEABILITY OF LATEX AND THERMOPLASTIC ELASTOMER GLOVES TO THE BACTERIOPHAGE PHI-X174
    HAMANN, CP
    NELSON, JR
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 1993, 21 (06) : 289 - 296
  • [8] ALLERGIC AND IRRITANT REACTIONS TO RUBBER GLOVES IN MEDICAL HEALTH-SERVICES - SPECTRUM, DIAGNOSTIC-APPROACH, AND THERAPY
    HEESE, A
    VONHINTZENSTERN, J
    PETERS, KP
    KOCH, HU
    HORNSTEIN, OP
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1991, 25 (05) : 831 - 839
  • [9] A prospective, controlled study showing that rubber gloves are the major contributor to latex aeroallergen levels in the operating room
    Heilman, DK
    Jones, RT
    Swanson, MC
    Yunginger, JW
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (02) : 325 - 330
  • [10] AN EPIDEMIC OF OCCUPATIONAL ALLERGY TO LATEX IVOLVING HEALTH-CARE WORKERS
    HUNT, LW
    FRANSWAY, AF
    REED, CE
    MILLER, LK
    JONES, RT
    SWANSON, MC
    YUNGINGER, JW
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1995, 37 (10) : 1204 - 1209