Automated metabolic profiling and interpretation of GC/MS data for organic acidemia screening: A personal computer-based system

被引:65
作者
Kimura, H
Yamamoto, T
Seiji, Y
机构
[1] Shimane Med Univ, Dept Pediat, Izumo, Shimane 6938501, Japan
[2] Shimadzu SD Co, Kyoto 6048435, Japan
关键词
organic acidemia; diagnostic algorithm; mass screening; GC/MS;
D O I
10.1620/tjem.188.317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have developed a personal computer-based system designed for automated metabolic profiling of urinary organic acids by gas chromatography-mass spectrometry (GC/MS) and data interpretation for organic acidemia screening. For the automated profiling, we compiled retention indices, two target ions and their intensity ratio for 126 urinary metabolites. Metabolites above the cut-off values were flagged as abnormal compounds. The data interpretation was based on combination of the flagged metabolites. Diagnostic or index metabolites mere categorized into three groups, "AND," "OR" and "NO," and compiled for each disorder to improve the specificity of the diagnosis. Groups "AND" and "OR" comprised essential and optional compounds, respectively, which and both to reach a specific diagnosis. Group "NO" comprised metabolites that must be absent to make a definite diagnosis. We tested this system by analyzing urine specimens from 48 patients previously diagnosed as having organic acidemias. In all cases. the diagnostic metabolites mere identified and each correct diagnosis could be found among the possible diseases suggested by the system Hence, with this simplified automated system, more people will be able to participate extensively in any screening programs using GC/MS. (C) 1999 Tohoku University Medical Press.
引用
收藏
页码:317 / 334
页数:18
相关论文
共 14 条
  • [1] Fenton WA, 1995, METABOLIC MOL BASES, P1423
  • [2] AUTOMATED SIMULTANEOUS QUALITATIVE AND QUANTITATIVE-ANALYSIS OF COMPLEX ORGANIC MIXTURES WITH A GAS CHROMATOGRAPHY-MASS SPECTROMETRY COMPUTER SYSTEM
    GATES, SC
    SMISKO, MJ
    ASHENDEL, CL
    YOUNG, ND
    HOLLAND, JF
    SWEELEY, CC
    [J]. ANALYTICAL CHEMISTRY, 1978, 50 (03) : 433 - 441
  • [3] GATES SC, 1978, CLIN CHEM, V24, P1663
  • [4] QUANTITATIVE-ANALYSIS OF BRANCHED-CHAIN ALPHA-KETO ACIDS AS THEIR TRIMETHYLSILYLATED OXIMES
    LANCASTER, G
    LAMM, P
    SCRIVER, CR
    TJOA, SS
    MAMER, OA
    [J]. CLINICA CHIMICA ACTA, 1973, 48 (03) : 279 - 285
  • [5] ORGANIC ACIDURIAS AND RELATED ABNORMAL
    LEHOTAY, DC
    CLARKE, JTR
    [J]. CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1995, 32 (04) : 377 - 429
  • [6] Matsumoto I, 1996, MASS SPECTROM REV, V15, P43, DOI 10.1002/(SICI)1098-2787(1996)15:1<43::AID-MAS3>3.0.CO
  • [7] 2-B
  • [8] TANDEM MASS-SPECTROMETRY - A NEW METHOD FOR ACYLCARNITINE PROFILING WITH POTENTIAL FOR NEONATAL SCREENING FOR INBORN-ERRORS OF METABOLISM
    MILLINGTON, DS
    KODO, N
    NORWOOD, DL
    ROE, CR
    [J]. JOURNAL OF INHERITED METABOLIC DISEASE, 1990, 13 (03) : 321 - 324
  • [9] DIAGNOSIS OF INBORN-ERRORS OF METABOLISM FROM BLOOD SPOTS BY ACYLCARNITINES AND AMINO-ACIDS PROFILING USING AUTOMATED ELECTROSPRAY TANDEM MASS-SPECTROMETRY
    RASHED, MS
    OZAND, PT
    BUCKNALL, MP
    LITTLE, D
    [J]. PEDIATRIC RESEARCH, 1995, 38 (03) : 324 - 331
  • [10] SCHOEMAKER JD, 1991, J CHROMATOGR, V562, P125