A computational reaction-diffusion model for the analysis of transport-limited kinetics

被引:83
作者
Vijayendran, RA
Ligler, FS
Leckband, DE [1 ]
机构
[1] Univ Illinois, Dept Chem Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Ctr Biophys & Computat Biol, Urbana, IL 61801 USA
[3] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
关键词
D O I
10.1021/ac990672b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optical, evanescent wave biosensors have become popular tools for quantitatively characterizing the kinetic properties of biomolecular interactions. Analyzing data from biosensor experiments, however, is often complicated when mass-transfer influences the detection kinetics. We present a computational, transport-kinetic model that can be used to analyze transport-limited biosensor data. This model describes a typical biosensor experiment in which a soluble analyte diffuses through a flow chamber and binds to a receptor immobilized on the transducer surface. Analyte transport in the flow chamber is described by the diffusion equation while the kinetics of analyte-surface association and dissociation are captured by a reactive boundary condition at the sensor surface. Numerical integration of the model equations and nonlinear least-squares fitting are used to compare model kinetic data to experimental results and generate estimates for the rate constants that describe analyte detection. To demonstrate the feasibility of this model, we use it to analyze data collected for the binding of fluorescently labeled trinitrobenzene to immobilized monoclonal anti-TNT antibodies, A successful analysis of this antigen-antibody interaction is presented for data collected with a fluorescence-based fiber-optic immunoassay, The results of this analysis are compared with the results obtained with existing methods for analyzing diffusion-limited kinetic data.
引用
收藏
页码:5405 / 5412
页数:8
相关论文
共 14 条
[1]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[2]  
Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond
[3]   FLUOROMETER AND TAPERED FIBER OPTIC PROBES FOR SENSING IN THE EVANESCENT WAVE [J].
GOLDEN, JP ;
SHRIVERLAKE, LC ;
ANDERSON, GP ;
THOMPSON, RB ;
LIGLER, FS .
OPTICAL ENGINEERING, 1992, 31 (07) :1458-1462
[4]  
LINDQUIST CKM, 1998, THESIS STAT U NEW YO
[5]   Kinetic analysis of a protein antigen-antibody interaction limited by mass transport on an optical biosensor [J].
Myszka, DG ;
Morton, TA ;
Doyle, ML ;
Chaiken, IM .
BIOPHYSICAL CHEMISTRY, 1997, 64 (1-3) :127-137
[6]   Extending the range of rate constants available from BIACORE: Interpreting mass transport-influenced binding data [J].
Myszka, DG ;
He, X ;
Dembo, M ;
Morton, TA ;
Goldstein, B .
BIOPHYSICAL JOURNAL, 1998, 75 (02) :583-594
[7]   Fiber optic-based biosensor for ricin [J].
Narang, U ;
Anderson, GP ;
Ligler, FS ;
Burans, J .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) :937-945
[8]  
Press W. H., 1997, NUMERICAL RECIPES C
[9]  
Schiesser W. E., 1991, NUMERICAL METHOD LIN
[10]   Kinetics of ligand binding to receptor immobilized in a polymer matrix, as detected with an evanescent wave biosensor .1. A computer simulation of the influence of mass transport [J].
Schuck, P .
BIOPHYSICAL JOURNAL, 1996, 70 (03) :1230-1249