Process-based quality management for clinical implementation of adaptive radiotherapy

被引:53
作者
Noel, Camille E. [1 ]
Santanam, Lakshmi [1 ]
Parikh, Parag J. [1 ]
Mutic, Sasa [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
关键词
adaptive radiotherapy; ART; FMEA; patient safety; QA; MODULATED RADIATION-THERAPY; REAL-TIME VERIFICATION; ASSURANCE; SYSTEM; TOOL;
D O I
10.1118/1.4890589
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: Intensity-modulated adaptive radiotherapy (ART) has been the focus of considerable research and developmental work due to its potential therapeutic benefits. However, in light of its unique quality assurance (QA) challenges, no one has described a robust framework for its clinical implementation. In fact, recent position papers by ASTRO and AAPM have firmly endorsed pretreatment patient-specific IMRT QA, which limits the feasibility of online ART. The authors aim to address these obstacles by applying failure mode and effects analysis (FMEA) to identify high-priority errors and appropriate risk-mitigation strategies for clinical implementation of intensity-modulated ART. Methods: An experienced team of two clinical medical physicists, one clinical engineer, and one radiation oncologist was assembled to perform a standard FMEA for intensity-modulated ART. A set of 216 potential radiotherapy failures composed by the forthcoming AAPM task group 100 (TG-100) was used as the basis. Of the 216 failures, 127 were identified as most relevant to an ART scheme. Using the associated TG-100 FMEA values as a baseline, the team considered how the likeliness of occurrence (0), outcome severity (S), and likeliness of failure being undetected (D) would change for ART. New risk priority numbers (RPN) were calculated. Failures characterized by RPN >= 200 were identified as potentially critical. Results: FMEA revealed that ART RPN increased for 38% (n = 48/127) of potential failures, with 75% (n = 36/48) attributed to failures in the segmentation and treatment planning processes. Fortythree of 127 failures were identified as potentially critical. Risk-mitigation strategies include implementing a suite of quality control and decision support software, specialty QA software/hardware tools, and an increase in specially trained personnel. Conclusions: Results of the FMEA-based risk assessment demonstrate that intensity-modulated ART introduces different (but not necessarily more) risks than standard IMRT and may be safely implemented with the proper mitigations. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 24 条
[1]
Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology [J].
Ford, Eric C. ;
Terezakis, Stephanie ;
Souranis, Annette ;
Harris, Kendra ;
Gay, Hiram ;
Mutic, Sasa .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03) :E263-E269
[2]
Fuangrod T., 2011, World Academy of Science, Engineering and Tech, V80, P609
[3]
Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor [J].
Goulet, Mathieu ;
Gingras, Luc ;
Beaulieu, Luc .
MEDICAL PHYSICS, 2011, 38 (03) :1459-1467
[4]
Hug M. S., 2008, INT J RADIAT ONCOL, V71, pS170
[5]
An integral quality monitoring system for real-time verification of intensity modulated radiation therapy [J].
Islam, Mohammad K. ;
Norrlinger, Bernhard D. ;
Smale, Jason R. ;
Heaton, Robert K. ;
Galbraith, Duncan ;
Fan, Cary ;
Jaffray, David A. .
MEDICAL PHYSICS, 2009, 36 (12) :5420-5428
[6]
Image-guided radiotherapy: from current concept to future perspectives [J].
Jaffray, David A. .
NATURE REVIEWS CLINICAL ONCOLOGY, 2012, 9 (12) :688-699
[7]
Real-Time Dose Reconstruction for Treatment Monitoring [J].
Jiang, Y. ;
Gu, X. ;
Men, C. ;
Jia, X. ;
Li, R. ;
Lewis, J. ;
Jiang, S. .
MEDICAL PHYSICS, 2010, 37 (06)
[8]
An Electronic Whiteboard and Associated Databases for Physics Workflow Coordination in a Paperless, Multi-Site Radiation Oncology Department [J].
Mallalieu, L. Brewster ;
Kapur, A. ;
Sharma, A. ;
Potters, L. ;
Jamshidi, A. ;
Pinsky, J. .
MEDICAL PHYSICS, 2011, 38 (06)
[9]
EXPERIENCE-BASED QUALITY CONTROL OF CLINICAL INTENSITY-MODULATED RADIOTHERAPY PLANNING [J].
Moore, Kevin L. ;
Brame, R. Scott ;
Low, Daniel A. ;
Mutic, Sasa .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02) :545-551
[10]
Quality Assurance With Plan Veto: Reincarnation of a Record and Verify System and Its Potential Value [J].
Noel, Camille E. ;
Gutti, VeeraRajesh ;
Bosch, Walter ;
Mutic, Sasa ;
Ford, Eric ;
Terezakis, Stephanie ;
Santanam, Lakshmi .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (05) :1161-1166