Bone growth in biomimetic apatite coated porous Polyactive® 1000PEGT70PBT30 implants

被引:58
作者
Du, C
Meijer, GJ
van de Valk, C
Haan, RE
Bezemer, JM
Hesseling, SC
Cui, FZ
de Groot, K
Layrolle, P
机构
[1] IsoTis NV, NL-3723 MB Bilthoven, Netherlands
[2] Leiden Univ, Biomat Res Grp, NL-2300 RA Leiden, Netherlands
[3] Univ Utrecht, Fac Med, Dept Oral Maxillofacial Surg, NL-3521 GD Utrecht, Netherlands
[4] Tsing Hua Univ, Dept Mat Sci & Engn, Hsinchu, Taiwan
关键词
biomimetic coating; apatite; Polyactive((R)) 1000PEGT70PBT30; bone growth;
D O I
10.1016/S0142-9612(02)00214-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We recently, developed a simple one-day one-step incubation method to obtain bone-like apatite coating on flexible and biodegradable Polyactive(R) 1000PEGT70PBT30. The present study reports a preliminary biological evaluation on the coated polymer after implantation in rabbit femurs. The porous cylindrical implants were produced from a block fabricated by injection molding and salt leaching. This technique provided the block necessary mechanical integrity to make small cylinders (diameter 3.5 x 5 mm(2)) that were suitable for implantation in rabbits. The coating continuously covered the surface of the polymer, preserving the porous architecture of outer contour of the cylinders. Two defects with a diameter of 3.5 or 4 mm were drilled in the proximal and distal part of femur diaphysis. The implants were inserted as press-fit or undersized into the cortex as well as in the marrow cavity. The polymer swelled after implantation due to hydration, leading to a tight contact with the surrounding bone in both defects. The adherence of the coating on the polymer proved to be sufficient to endure a steam sterilization process as well as the 15% swelling of the polymer in vivo. The coated Polyactive(R) 1000PEGT70PBT30 has a good osteoconductive property, as manifested by abundant bone growth into marrow cavity along the implant surface during 4-week implantation. A favorable bioactive effect of the coating with an intimate bone contact and extensive bone bonding with this polymer was qualitatively confirmed. Concerning the bone ingrowth into the porous implant in the defect of 4 mm diameter, only marginal bone formation was observed up to 8 weeks with a maximal penetration depth of about 1 mm. The pore interconnectivity is important not only for producing a coating inside the porous structure but also for bone ingrowth into this biodegradable material. This preliminary study provided promising evidence for a further study using a bigger animal model. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4649 / 4656
页数:8
相关论文
共 39 条
  • [1] Biomimetic calcium phosphate coatings on Ti6Al4V:: A crystal growth study of octacalcium phosphate and inhibition by Mg2+ and HCO3-
    Barrère, F
    Layrolle, P
    Van Blitterswijk, CA
    De Groot, K
    [J]. BONE, 1999, 25 (02) : 107S - 111S
  • [2] Quantitative histological analysis of bony ingrowth within the biomaterial Polyactive™ implanted in different bone locations:: an experimental study in rabbits
    Bouwmeester, SJM
    Kuijer, R
    Sollie-Drees, MMWE
    Van der Linden, AJ
    Bulstra, SK
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (04) : 181 - 185
  • [3] BONE TISSUE ENGINEERING
    CRANE, GM
    ISHAUG, SL
    MIKOS, AG
    [J]. NATURE MEDICINE, 1995, 1 (12) : 1322 - 1324
  • [4] Doi Y, 1996, J BIOMED MATER RES, V31, P43, DOI 10.1002/(SICI)1097-4636(199605)31:1<43::AID-JBM6>3.0.CO
  • [5] 2-Q
  • [6] Biomimetic calcium phosphate coatings on Polyactive® 1000/70/30
    Du, C
    Klasens, P
    Haan, RE
    Bezemer, J
    Cui, FZ
    de Groot, K
    Layrolle, P
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 59 (03): : 535 - 546
  • [7] Du C, 2000, J BIOMED MATER RES, V50, P518, DOI 10.1002/(SICI)1097-4636(20000615)50:4<518::AID-JBM7>3.0.CO
  • [8] 2-W
  • [9] GAILLARD M, 1995, THESIS NETHERLANDS U
  • [10] James K S, 1999, Methods Mol Med, V18, P121, DOI 10.1385/0-89603-516-6:121