Comparison of hemolysis in blood samples collected using an automatic incision device and a manual lance

被引:12
作者
Kazmierczak, SC
Robertson, AF
Briley, KP
机构
[1] Oregon Hlth & Sci Univ, Dept Pathol, Portland, OR 97201 USA
[2] Brody Sch Med E Carolina, Dept Pediat, Greenville, NC USA
[3] Brody Sch Med E Carolina, Dept Pathol, Greenville, NC USA
[4] Brody Sch Med E Carolina, Dept Lab Med, Greenville, NC USA
来源
ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE | 2002年 / 156卷 / 11期
关键词
D O I
10.1001/archpedi.156.11.1072
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To evaluate the magnitude of hemolysis in blood specimens collected from the heels of newborns using an automated blood collection device that uses a spring-loaded lance with blood collected using a manual lance. Design: A randomized controlled trial involving 134 newborns assigned to have blood collected using either an automated blood collection device or a manual lance. A single experienced individual performed all blood collections. Serum hemoglobin concentrations were measured in all samples to gauge the extent of hemolysis. Setting: A neonatology unit in a 740-bed tertiary care teaching hospital. Patients: Healthy newborns with gestational ages ranging from 33 weeks to 41 weeks. Blood samples were collected from study participants at between 7 and 126 hours postpartum. Group I consisted of 66 individuals who had blood collected using the manual lance. Group 2 contained 68 individuals with blood collected using a spring-loaded automatic lance. Main Outcome Measure: Plasma hemoglobin content as an indicator of the extent of hemolysis. Results: There were no significant differences between newborns in groups I and 2 with respect to gestational age, birth weight, or time interval between birth and time of blood collection. We found a highly significant difference with respect to plasma hemoglobin concentrations in specimens collected with an automated lance (hemoglobin, 2.35 g/L) vs that collected using the hand-held lance (hemoglobin, 4.85 g/L). Conclusion: Use of an automated spring-loaded lance allows for the collection of blood specimens with smaller levels of plasma hemoglobin.
引用
收藏
页码:1072 / 1074
页数:3
相关论文
共 12 条
[1]   HEEL BLOOD-SAMPLING IN PRETERM INFANTS - WHICH TECHNIQUE [J].
BARKER, DP ;
LATTY, BW ;
RUTTER, N .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1994, 71 (03) :F206-F208
[2]  
BHUTANI VK, PEDIATRICS
[3]  
BROWN L, 1987, NEONATAL NETWORK, V5, P18
[4]   THE SCARS OF NEWBORN INTENSIVE-CARE [J].
CARTLIDGE, PHT ;
FOX, PE ;
RUTTER, N .
EARLY HUMAN DEVELOPMENT, 1990, 21 (01) :1-10
[5]  
GLICK MR, 1989, CLIN CHEM, V35, P837
[6]   MAKING HEEL PRICKS LESS PAINFUL [J].
HARPIN, VA ;
RUTTER, N .
ARCHIVES OF DISEASE IN CHILDHOOD, 1983, 58 (03) :226-228
[7]  
Jones BA, 1997, ARCH PATHOL LAB MED, V121, P19
[8]  
MATTHEWS D, 1992, NEONATAL INTENSI MAY, P66
[9]   ALLEVIATION OF THE PAIN OF HEEL PRICK IN PRETERM INFANTS [J].
MCINTOSH, N ;
VANVEEN, L ;
BRAMEYER, H .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1994, 70 (03) :F177-F181
[10]   PAIN IN INFANCY - NEONATAL REACTION TO A HEEL LANCE [J].
OWENS, ME ;
TODT, EH .
PAIN, 1984, 20 (01) :77-86