An automated registration algorithm for measuring MRI subcortical brain structures

被引:108
作者
Iosifescu, DV
Shenton, ME
Warfield, SK
Kikinis, R
Dengler, J
Jolesz, FA
McCarley, RW
机构
[1] BRIGHAM & WOMENS HOSP,MRI DIV,DEPT RADIOL,SURG PLANNING LAB,BOSTON,MA 02115
[2] UNIV NEW S WALES,SCH ENGN & COMP SCI,SYDNEY,NSW 2052,AUSTRALIA
[3] GERMAN CANC RES INST,D-69120 HEIDELBERG,GERMANY
关键词
D O I
10.1006/nimg.1997.0274
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
An automated registration algorithm was used to elastically match an anatomical magnetic resonance (MR) atlas onto individual brain MR images. Our goal was to evaluate the accuracy of this procedure for measuring the volume of MRI brain structures. We applied two successive algorithms to a series of 28 MR brain images, from 14 schizophrenia patients and 14 normal controls. First, we used an automated segmentation program to differentiate between white matter, cortical and subcortical gray matter, and cerebrospinal fluid. Next, we elastically deformed the atlas segmentation to fit the subject's brain, by matching the white matter and subcortical gray matter surfaces, To assess the accuracy of these measurements, we compared, on all 28 images, 11 brain structures, measured with elastic matching, with the same structures traced manually on MRI scans. The similarity between the measurements (the relative difference between the manual and the automated volume) was 97% for whole white matter, 92% for whole gray matter, and on average 89% for subcortical structures, The relative spatial overlap between the manual and the automated volumes was 97% for whole white matter, 92% for whole gray matter, and on average 75% for subcortical structures. For all pairs of structures rendered with the automated and the manual method, Pearson correlations were between r = 0.78 and r = 0.98 (P < 0.01, N = 28), except for globus pallidus, where r = 0.55 (left) and r = 0.44 (right) (P < 0.01,N = 28). In the schizophrenia group, compared to the controls, we found a 16.7% increase in MRI volume for the basal ganglia (i.e., caudate nucleus, putamen, and globus pallidus), but no difference in total gray/white matter volume or in thalamic MR volume. This finding reproduces previously reported results, obtained in the same patient population with manually drawn structures, and suggests the utility/efficacy of our automated registration algorithm over more labor-intensive manual tracings. (C) 1997 Academic Press.
引用
收藏
页码:13 / 25
页数:13
相关论文
共 27 条
[1]   Automatic atlas-based volume estimation of human brain regions from MR images [J].
Andreasen, NC ;
Rajarethinam, R ;
Cizadlo, T ;
Arndt, S ;
Swayze, VW ;
Flashman, LA ;
OLeary, DS ;
Ehrhardt, JC ;
Yuh, WTC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (01) :98-106
[2]   MULTIRESOLUTION ELASTIC MATCHING [J].
BAJCSY, R ;
KOVACIC, S .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1989, 46 (01) :1-21
[3]  
CHRISTENSEN GE, 1993, PROCEEDINGS OF THE TWENTY-SEVENTH ANNUAL CONFERENCE ON INFORMATION SCIENCES AND SYSTEMS, P211
[4]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[5]  
COLLINS DL, 1992, SPIE VISUALIZAT BIOM, P10
[6]   EVALUATION OF ELASTIC MATCHING SYSTEM FOR ANATOMIC (CT, MR) AND FUNCTIONAL (PET) CEREBRAL IMAGES [J].
DANN, R ;
HOFORD, J ;
KOVACIC, S ;
REIVICH, M ;
BAJCSY, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (04) :603-611
[7]  
Dengler J., 1988, International Journal of Pattern Recognition and Artificial Intelligence, V2, P275, DOI 10.1142/S0218001488000170
[8]  
Dhawan Atam P., 1992, American Journal of Physiologic Imaging, V7, P210
[9]  
EVANS AC, 1991, SPIE, V1445, P236
[10]   ELASTICALLY DEFORMING 3D ATLAS TO MATCH ANATOMICAL BRAIN IMAGES [J].
GEE, JC ;
REIVICH, M ;
BAJCSY, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) :225-236