Correction of temperature-induced spectral variation by continuous piecewise direct standardization

被引:85
作者
Wulfert, F
Kok, WT
de Noord, OE
Smilde, AK
机构
[1] Univ Amsterdam, Dept Chem Engn Proc Anal & Chemometr, NL-1018 WV Amsterdam, Netherlands
[2] Shell Int Chem BV, Shell Res & Technol Ctr, NL-1030 BN Amsterdam, Netherlands
关键词
D O I
10.1021/ac9906835
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In process analytical applications it is not always possible to keep the measurement conditions constant. Ho However, fluctuations in esternal variables such as temperature can have a strong influence on measurement results. For example, nonlinear temperature effects on near-infrared (NIR) spectra may lead to a strongly biased prediction result from multivariate calibration models such as PLS. A new method, called Continuous Piecewise Direct Standardization (CPDS) has been developed for the correction of such external influences. It represents a generalization of the discrete PDS calibration transfer method and is able to adjust for continuous nonlinear influences such as the temperature effects on spectra. It was applied to shortwave NIR spectra of ethanol/water/2-propanol mixtures measured at different temperatures in the range 30-70 degrees C. The method was able to remove, almost completely, the temperature effects on the spectra, and prediction of the mole fractions of the chemical components was close to the results obtained at constant temperature.
引用
收藏
页码:1639 / 1644
页数:6
相关论文
共 39 条
[1]   PLS regression methods [J].
Höskuldsson, Agnar .
Journal of Chemometrics, 1988, 2 (03) :211-228
[2]   PROCESS ANALYTICAL-CHEMISTRY [J].
BLASER, WW ;
BREDEWEG, RA ;
HARNER, RS ;
LAPACK, MA ;
LEUGERS, A ;
MARTIN, DP ;
PELL, RJ ;
WORKMAN, J ;
WRIGHT, LG .
ANALYTICAL CHEMISTRY, 1995, 67 (12) :R47-R70
[3]   Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration [J].
Bouveresse, E ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) :201-213
[4]   INTRAMOLECULAR HYDROGEN-BOND AND MOLECULAR-CONFORMATION .2. EFFECT OF PRESSURE AND TEMPERATURE ON THE IR-SPECTRA OF SOME HYDROXY KETONES [J].
CHO, T ;
KIDA, I ;
NINOMIYA, J ;
IKAWA, S .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (01) :103-107
[5]   Comparison of near-IR, Raman, and mid-IR spectroscopies for the determination of BTEX in petroleum fuels [J].
Cooper, JB ;
Wise, KL ;
Welch, WT ;
Sumner, MB ;
Wilt, BK ;
Bledsoe, RR .
APPLIED SPECTROSCOPY, 1997, 51 (11) :1613-1620
[6]   ARE THE INTEGRATED ABSORPTION-COEFFICIENTS TEMPERATURE-DEPENDENT - FT-NIR STUDY OF THE 1ST OVERTONE OF THE OH STRETCHING MODE OF OCTANOIC-ACID [J].
CZARNECKI, MA ;
CZARNECKA, M ;
OZAKI, Y ;
IWAHASHI, M .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1994, 50 (8-9) :1521-1528
[7]   POTENTIAL OF FOURIER-TRANSFORM NEAR-INFRARED SPECTROSCOPY IN STUDIES OF THE DISSOCIATION OF FATTY-ACIDS IN THE LIQUID-PHASE [J].
CZARNECKI, MA ;
LIU, YL ;
OZAKI, Y ;
SUZUKI, M ;
IWAHASHI, M .
APPLIED SPECTROSCOPY, 1993, 47 (12) :2162-2168
[8]  
DAILEY WV, 1992, PROCESS CONTR QUAL, V3, P99
[9]   Influence and correction of temperature perturbations on NIR spectra during the monitoring of a polymorph conversion process prior to self-modelling mixture analysis [J].
DeBraekeleer, K ;
Sanchez, FC ;
Hailey, PA ;
Sharp, DCA ;
Pettman, AJ ;
Massart, DL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (01) :141-152
[10]   REAL-TIME MONITORING OF POLYURETHANE PRODUCTION USING NEAR-INFRARED SPECTROSCOPY [J].
DETHOMAS, FA ;
HALL, JW ;
MONFRE, SL .
TALANTA, 1994, 41 (03) :425-431