A model for dose-rate dependence of thermoluminescence intensity

被引:27
作者
Chen, R [1 ]
Leung, PL
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Tel Aviv Univ, Raymond & Beverly Sackler Fac Exact Sci, Sch Phys & Astron, IL-69978 Tel Aviv, Israel
关键词
D O I
10.1088/0022-3727/33/7/315
中图分类号
O59 [应用物理学];
学科分类号
摘要
In the applications of thermoluminescence (TL) in dosimetry and archaeological dating, it is usually assumed that the measured TL depends on the total dose applied and it is independent of the dose rate. Thus, calibration of a TL specimen is usually performed at a significantly higher dose rate than that of the dose to be determined. A few experimental accounts in the literature report on dose-rate dependences of TL intensity for a given total dose. One theoretical work published gave a numerical solution of the simultaneous differential equations governing the filling of traps and centres at different dose rates. In the present work, the numerical solution is extended so that it includes the other important stage of TL, namely the heating phase. It is shown that with a rather simple model of one trapping stale and two kinds of recombination centres, dose-rate effects may occur. An appropriate choice of the relevant parameters indeed yields one emission, which increases with increasing dose rate, whereas another emission decreases with the dose rate with a constant total dose, in agreement with an experimental result in quartz quoted in the literature.
引用
收藏
页码:846 / 850
页数:5
相关论文
共 20 条
[1]  
AITKEN M, 1974, PHYSICS ARCHAEOLOGY
[2]   Study of the energy deposition in LiF by heavy charged particle irradiation and its relation to the thermoluminescent efficiency of the material [J].
Avila, O ;
Gamboa-deBuen, I ;
Brandan, ME .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (10) :1175-1181
[3]  
Cameron JR., 1968, THERMOLUMINESCENT DO
[4]   Quartz thermoluminescence: Dose and dose-rate effects and their implications [J].
Chawla, S ;
Rao, TKG ;
Singhvi, AK .
RADIATION MEASUREMENTS, 1998, 29 (01) :53-63
[5]  
CHEN CC, 1982, LIGHT MET, V6, P295
[6]   SOLUTION OF THE KINETIC-EQUATIONS GOVERNING TRAP FILLING - CONSEQUENCES CONCERNING DOSE DEPENDENCE AND DOSE-RATE EFFECTS [J].
CHEN, R ;
MCKEEVER, SWS ;
DURRANI, SA .
PHYSICAL REVIEW B, 1981, 24 (09) :4931-4944
[7]  
Durrani S. A., 1978, EUROP PACT J, V2, P200
[8]  
FACEY RA, 1966, HEALTH PHYS, V12, P717
[9]   REAFFIRMATION ON THE LOW EXPOSURE RATE DEPENDENCE OF THE CASO4-DY THERMOLUMINESCENT DOSIMETER [J].
HSU, PC ;
WENG, PS .
NUCLEAR INSTRUMENTS & METHODS, 1980, 174 (1-2) :73-76
[10]  
HUNTLEY DJ, 1988, NUCL TRACKS RAD MEAS, V14, P27