Influence of combustion conditions on the PCDD/F-, PCB-, PCBz- and PAH-concentrations in the post-combustion chamber of a waste incineration pilot plant

被引:71
作者
Blumenstock, M
Zimmermann, R [1 ]
Schramm, KW
Kettrup, A
机构
[1] Tech Univ Munich, Lehrstuhl Okol Chem & Umweltanalyt, D-85354 Freising, Germany
[2] GSF, Forschzentrum Umwelt & Gesundheit, Inst Okol Chem, D-85764 Neuherberg, Germany
关键词
waste incineration; post combustion chamber; flue gas; PCDD/F; I-TEQ; PCB; PCBz; PAH; principle component analysis (PCA); memory effects; surrogate compounds; REMPI-TOFMS;
D O I
10.1016/S0045-6535(99)00343-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Experiments at a pilot scale waste incinerator (0.5 MW thermal power) showed that the conditions in the postcombustion chamber (650-900 degrees C) are strongly influencing the formation of chlorinated and non-chlorinated aromatics. Non-optimal combustion conditions resulted in increased concentrations of mono- to trichlorinated dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and polycyclic aromatic hydrocarbons (PAH), while chlorinated benzenes (PCBz), polychlorinated biphenyls (PCB) and the higher chlorinated PCDD/F are only weakly affected or even decrease. The changes in concentration of the compounds investigated over a time span of hours gave hints on 'memory effects' in this combustion zone. For mono- and dichlorinated benzenes, a high correlation (r(2) = 0.80) with the international toxicity equivalent (I-TEQ) value of PCDD/F was observed. As recently has been demonstrated, this correlation can be utilized for an indirect on-line measurement of the I-TEQ by a novel laser mass spectrometric technique (REMPI-TO-FMS). (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:987 / 993
页数:7
相关论文
共 28 条
[1]   PROFILE AND PATTERN OF MONOCHLORODIBENZODIOXINS THROUGH OCTACHLORODIBENZODIOXINS AND OCTACHLORODIBENZOFURANS IN CHIMNEY DEPOSITS FROM WOOD BURNING [J].
BACHER, R ;
SWEREV, M ;
BALLSCHMITER, K .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (08) :1649-1655
[2]  
BECKMANN M, 1997, P 5 INT C 97 INFUB F, V1
[3]  
BEHROOZ SG, 1996, HAZARDOUS WASTE HAZA, V13, P11
[4]   Estimation of the dioxin emission (PCDD/FI-TEQ) from the concentration of low chlorinated aromatic compounds in the flue and stack gas of a hazardous waste incinerator [J].
Blumenstock, M ;
Zimmermann, R ;
Schramm, KW ;
Kaune, A ;
Nikolai, U ;
Lenoir, D ;
Kettrup, A .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1999, 49 (1-2) :179-190
[5]  
CHOUDRY G, 1983, MECH ASPECTS THERMAL, P67
[6]  
FANGMARK I, 1993, ENVIRON SCI TECHNOL, V27, P1602
[7]  
GULLETT BK, 1998, ORGANOHALOGEN COMPOU, V36, P179
[8]  
Hagenmaier H, 1987, VDI BER, V634, P557
[9]   On-line emission analysis of polycyclic aromatic hydrocarbons down to pptv concentration levels in the flue gas of an incineration pilot plant with a mobile resonance enhanced multiphoton ionization time-of-flight mass spectrometer [J].
Heger, HJ ;
Zimmermann, R ;
Dorfner, R ;
Beckmann, M ;
Griebel, H ;
Kettrup, A ;
Boesl, U .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :46-57
[10]  
Huang JW, 1996, TWENTY-SIXTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P2335