Gamma Nails Revisited: Gamma Nails Versus Compression Hip Screws in the Management of Intertrochanteric Fractures of the Hip: A Meta-Analysis

被引:142
作者
Bhandari, Mohit [1 ]
Schemitsch, Emil [2 ]
Joensson, Anders [3 ]
Zlowodzki, Michael [3 ]
Haidukewych, George J. [4 ]
机构
[1] McMaster Univ, Div Orthopaed Surg, Hamilton, ON L8L 2X2, Canada
[2] Univ Toronto, Div Orthopaed Surg, Toronto, ON, Canada
[3] Stryker Res & Dev, Kiel, Germany
[4] Florida Orthopaed Inst, Tampa, FL USA
关键词
meta-analysis; Gamma nail; sliding hip screw; outcomes; intramedullary nail; PROXIMAL FEMORAL NAIL; TROCHANTERIC FRACTURES; INTRAMEDULLARY NAIL; ELDERLY-PATIENTS; CONTROLLED-TRIAL; PLATE; FIXATION; FEMUR;
D O I
10.1097/BOT.0b013e318162f67f
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Concerns about the Gamma nail have largely been fueled by early randomized trials and meta-analyses suggesting an increased risk of subsequent femoral shaft fractures when compared with compression hip screws. Whereas meta-analyses favor compression hip screws over first-generation Gamma nails, little is known as to whether the newer Gamma nail designs and the improved learning curve associated with the implants have reduced the risk of femoral shaft fracture. The current meta-analysis aimed to explore the effects of time and Gamma Nail design on the risks of femoral shaft fracture after treatment of extracapsular hip fractures. Methods: We searched computerized databases (Medline, Cochrane, and SciSearch) for published randomized clinical trials from 1969 to 2002, and we identified additional studies through hand searches of major orthopedic journals, bibliographies of major orthopedic texts, and personal files. Two investigators independently graded study quality and abstracted relevant data. We abstracted information on subsequent femoral shaft fracture rates from studies. We pooled data using a random-effects model and tested for heterogeneity using the 12 test. We conducted sensitivity analyses by date and by generation of the Gamma nail. We further conducted a cumulative meta-analysis to explore the treatment effect over time. Results: We identified 25 relevant randomized trials from 1991 to 2005. In earlier studies (N = 1585 patients), Gamma nails increased the risk of femoral shaft fracture 4.5 times compared with a compression hip screw (95% confidence interval: 1.78-11.36, P = 0.0014, I(2) = 0%). However, among the most recent studies (2000-2005), Gamma nails did not significantly increase femoral shaft fracture risk (relative risk = 1.65, 95% confidence interval: 0.50-5.44, P = 0.41, I(2) = 0%). The most recent study (2005) found no difference in femoral fracture rates (relative risk = 1.03, 95% confidence interval = 0.06-16.2, P = 0.99). Conclusions: Our meta-analysis of randomized trials suggests that previous concerns about increased femoral shaft fracture risk with Gamma nails have been resolved with improved implant design and improved learning curves with the device. Earlier meta-analyses and randomized trials should be interpreted with caution in light of more recent evidence.
引用
收藏
页码:460 / 464
页数:5
相关论文
共 24 条
[1]   Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]  
Ahrengart L, 2002, CLIN ORTHOP RELAT R, P209
[3]   GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS [J].
AUNE, AK ;
EKELAND, A ;
ODEGAARD, B ;
GROGAARD, B ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :127-130
[4]  
Baumgaertner MR, 1998, CLIN ORTHOP RELAT R, P87
[5]   THE TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES OF THE HIP - A PROSPECTIVE TRIAL OF 150 CASES [J].
BONG, SC ;
LAU, HK ;
LEONG, JCY ;
FANG, D ;
LAU, MT .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1981, 13 (02) :139-146
[6]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[7]   HIP-FRACTURES IN THE ELDERLY - A WORLDWIDE PROJECTION [J].
COOPER, C ;
CAMPION, G ;
MELTON, LJ .
OSTEOPOROSIS INTERNATIONAL, 1992, 2 (06) :285-289
[8]  
CUMMINGS SR, 1990, CLIN ORTHOP RELAT R, P163
[9]   Random-effects model for meta-analysis of clinical trials: An update [J].
DerSimonian, Rebecca ;
Kacker, Raghu .
CONTEMPORARY CLINICAL TRIALS, 2007, 28 (02) :105-114
[10]   Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: Preliminary results [J].
Dujardin, FH ;
Benez, C ;
Polle, G ;
Alain, J ;
Biga, N ;
Thomine, JM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :401-406