Right ventricular volume measurement using the conductance catheter method: Validation in excised porcine hearts

被引:4
作者
Danton, MHD [1 ]
Byrne, JG [1 ]
Hsin, M [1 ]
Laurence, R [1 ]
Cohn, LH [1 ]
Aklog, L [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Cardiac Surg Res Lab, Boston, MA 02115 USA
关键词
D O I
10.1097/00002480-200209000-00013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The conductance catheter method for measuring right ventricular (RV) volume changes was assessed in seven excised porcine hearts. A 5-FG conductance catheter was placed within a latex balloon and positioned in the RV cavity of seven freshly excised porcine hearts. Conductance was recorded while saline was withdrawn from the intraventricular balloon in 2 ml decrements. Linear regression analysis of measured conductance versus reference volumes was computed. The effect of left ventricular (LV) filling and catheter length on conductance derived RV volume was also determined. Conductance derived volumes were highly correlated with reference volumes [R-2 0.976, standard deviation (SD) 0.035]. The mean gradient of regression was 0.97 (SD 0.10), and it was not significantly affected by LV volume alterations. However, when we analyzed LV filling, a small but significant increase in the y-intercept was observed (LV empty 3.11 ml, SD 1.71; LV full 4.58, SD 2.39; p = 0.008). Introduction of the catheter through either the tricuspid or pulmonary orifices were both effective in ventricular volume measurement. The effect of mismatch between the catheter length and the RV long axis dimension was evaluated by changing the position of the active sensing electrodes along the catheter body. Conductance measurements, obtained from catheters shorter than the long axis of the RV, still maintained a highly linear correlation with real volume, but regression gradients were significantly reduced (long 0.975, SD 0.087; medium 0.787, SD 0.094; small 0.589, SD 0.091; p < 0.001). These results show that a conductance catheter of appropriate length can accurately measure RV volume, despite the complex shape and geometric changes associated with ventricular filling.
引用
收藏
页码:514 / 519
页数:6
相关论文
共 35 条
[1]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[2]   CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[3]   LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE [J].
BOLTWOOD, CM ;
APPLEYARD, RF ;
GLANTZ, SA .
CIRCULATION, 1989, 80 (05) :1360-1377
[4]   Validation of a new intraoperative technique to evaluate load-independent indices of right ventricular performance in patients undergoing cardiac operations [J].
Brookes, CIO ;
White, PA ;
Bishop, AJ ;
Oldershaw, PJ ;
Redington, AN ;
Noat, NE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (03) :468-476
[5]  
DEAN DA, 1995, ASAIO J, V41, pM673, DOI 10.1097/00002480-199507000-00096
[6]   ELLIPSOIDAL SHELL SUBTRACTION MODEL OF RIGHT VENTRICULAR VOLUME - COMPARISON WITH REGIONAL FREE WALL DIMENSIONS AS INDEXES OF RIGHT VENTRICULAR-FUNCTION [J].
FENELEY, MP ;
ELBEERY, JR ;
GAYNOR, JW ;
GALL, SA ;
DAVIS, JW ;
RANKIN, JS .
CIRCULATION RESEARCH, 1990, 67 (06) :1427-1436
[7]   SURGICAL REPAIR OF TRICUSPID ATRESIA [J].
FONTAN, F ;
BAUDET, E .
THORAX, 1971, 26 (03) :240-+
[8]  
Gorcsan J, 1996, AM HEART J, V131, P544
[9]   Measurement of left ventricular volume by dual-field conductance catheter in humans - Comparison with single-field conductance catheter [J].
Hayashi, Y ;
Takeuchi, M ;
Takaoka, H ;
Yokoyama, M .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1996, 60 (02) :85-95
[10]   CLINICAL-EVALUATION OF LEFT HEART FUNCTION BY CONDUCTANCE CATHETER TECHNIQUE [J].
KASS, DA .
EUROPEAN HEART JOURNAL, 1992, 13 :57-64