Comparison of 6 automated assays for total and free prostate-specific antigen with special reference to their reactivity toward the WHO 96/670 reference preparation

被引:65
作者
Kort, Sheila A. R.
Martens, Frans
Vanpoucke, Hilde
van Duijnhoven, Hans L.
Blankenstein, Marinus A.
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Clin Chem, Endocrine Lab, NL-1081 HV Amsterdam, Netherlands
[2] Clin Chem Lab, Roeselare Menen, Belgium
[3] Algemeen Klin Lab, Helmond, Netherlands
关键词
D O I
10.1373/clinchem.2006.069039
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Prostate-specific antigen (PSA) assays have historically produced different results. Our aim was to investigate the comparability of assay results of selected commercially available assay methods designed to measure total, free, or complexed PSA (tPSA, fPSA, and cPSA). Methods: We measured tPSA, fPSA, and cPSA in 70 samples and in the WHO PSA 96/670 reference preparation with 6 assays (Beckman-Coulter Access, Abbott ARCHITECT and AxSYM, Bayer Advia Centaur, DPC IMMULITE 2000, and Roche Modular Analytics E170). We also calculated the fPSA/tPSA ratio. Results: The mean deviations from the expected tPSA and fPSA values for the WHO 96/670 reference preparation were 0.37 (range, 0.01-1.32) and 0.19 (range, 0.050.49) fxg/L, respectively. When plotted against the expected WHO 96/670 reference preparation value, regression slopes varied from 0.99 to 1.22 and r(2) from 0.9996 to 1.000. When total PSA was measured in mixtures of sera with high and low tPSA concentrations, the mean (SD) slope of regression of different assays against an in-house method was 1.04 (0.09). In these specimens, the fPSA/tPSA ratio was 0.11-0.14 with different methods. The tPSA and fPSA values in patient samples measured in different assays and plotted against ARCHITECT gave regression slopes from 0.88 to 0.97. The results of the studied assays for tPSA in serum samples agreed within 15%, from each other, and all results for the WHO 96/670 reference preparation were within 6.8% (confidence interval, 1.7%-15.2%) of the expected value. The results for fPSA were more diverse. Conclusions: Differences among PSA assays appear to have decreased since introduction of the WHO 96/670 reference preparation, but further efforts are needed to harmonize fPSA assays. (c) 2006 American Association for Clinical Chemistry.
引用
收藏
页码:1568 / 1574
页数:7
相关论文
共 19 条
[1]   Prostate cancer screening in the prostate, lung, colorectal and Ovarian (PLCO) Cancer Screening Trial: Findings from the initial screening round of a randomized trial [J].
Andriole, GL ;
Levin, DL ;
Crawford, ED ;
Gelmann, ER ;
Pinsky, PF ;
Chia, D ;
Kramer, BS ;
Reding, D ;
Church, TR ;
Grubb, RL ;
Izmirlian, G ;
Ragard, LR ;
Clapp, JD ;
Prorok, PC ;
Gohagan, JK .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2005, 97 (06) :433-438
[2]  
ARMBRUSTER DA, 1993, CLIN CHEM, V39, P181
[3]  
Auvinen A, 1996, J Med Screen, V3, P97
[4]  
Blase AB, 1997, CLIN CHEM, V43, P843
[5]   Discordant performance of assays for free and total prostate-specific antigen in relation to the early detection of prostate cancer [J].
Blijenberg, BG ;
Yurdakul, G ;
Van Zelst, B ;
Bangma, CH ;
Wildhagen, MF ;
Schröder, FH .
BJU INTERNATIONAL, 2001, 88 (06) :545-550
[6]  
Chan DW, 2000, CLIN CHEM, V46, P1291
[7]   Strategies combining total and percent free prostate specific antigen for detecting prostate cancer: A prospective evaluation [J].
Gann, PH ;
Ma, J ;
Catalona, WJ ;
Stampfer, MJ .
JOURNAL OF UROLOGY, 2002, 167 (06) :2427-2434
[8]  
Gion M, 1998, CLIN CHEM, V44, P2462
[9]   Standardization of prostate-specific antigen (PSA) assays: Can interchangeability of PSA measurements be improved? [J].
Ishibashi, M .
CLINICAL CHEMISTRY, 2006, 52 (01) :1-2
[10]   A comparison of six commercial assays for total and free prostate specific antigen (PSA): the predictive value of the ratio of free to total PSA [J].
Patel, D ;
White, PAE ;
Ward, AM .
BJU INTERNATIONAL, 2000, 85 (06) :686-689