Environmental impacts of high penetration renewable energy scenarios for Europe

被引:89
作者
Berrill, Peter [1 ,2 ]
Arvesen, Anders [1 ,2 ]
Scholz, Yvonne [3 ]
Gils, Hans Christian [3 ]
Hertwich, Edgar G. [1 ,2 ,4 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Ind Ecol Programme, NTNU, Sem Saelands Vei 7, NO-7491 Trondheim, Norway
[2] Norwegian Univ Sci & Technol NTNU, Dept Energy & Proc Engn, NTNU, Sem Saelands Vei 7, NO-7491 Trondheim, Norway
[3] German Aerosp Ctr DLR, Inst Engn Thermodynam, Pfaffenwaldring 38-40, D-70569 Stuttgart, Germany
[4] Yale Univ, Sch Forestry& Environm Studies, Ctr Ind Ecol, New Haven, CT 06511 USA
来源
ENVIRONMENTAL RESEARCH LETTERS | 2016年 / 11卷 / 01期
关键词
life cycle assessment (LCA); electricity scenarios; power system; THEMIS; REMix; LIFE-CYCLE ASSESSMENT; GREENHOUSE-GAS EMISSIONS; ELECTRICITY-GENERATION; POWER; TECHNOLOGY;
D O I
10.1088/1748-9326/11/1/014012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The prospect of irreversible environmental alterations and an increasingly volatile climate pressurises societies to reduce greenhouse gas emissions, thereby mitigating climate change impacts. As global electricity demand continues to grow, particularly if considering a future with increased electrification of heat and transport sectors, the imperative to decarbonise our electricity supply becomes more urgent. This letter implements outputs of a detailed power system optimisation model into a prospective life cycle analysis framework in order to present a life cycle analysis of 44 electricity scenarios for Europe in 2050, including analyses of systems based largely on low-carbon fossil energy options (natural gas, and coal with carbon capture and storage (CCS)) as well as systems with high shares of variable renewable energy (VRE) (wind and solar). VRE curtailments and impacts caused by extra energy storage and transmission capabilities necessary in systems based on VRE are taken into account. The results show that systems based largely on VRE perform much better regarding climate change and other impact categories than the investigated systems based on fossil fuels. The climate change impacts from Europe for the year 2050 in a scenario using primarily natural gas are 1400 Tg CO2-eq while in a scenario using mostly coal with CCS the impacts are 480 Tg CO2-eq. Systems based on renewables with an even mix of wind and solar capacity generate impacts of 120-140 Tg CO2-eq. Impacts arising as a result of wind and solar variability do not significantly compromise the climate benefits of utilising these energy resources. VRE systems require more infrastructure leading to much larger mineral resource depletion impacts than fossil fuel systems, and greater land occupation impacts than systems based on natural gas. Emissions and resource requirements from wind power are smaller than from solar power.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] ABB, 2003, ENV PROD DECL POW TR
  • [2] ABB, 2000, ENV PROD DECL POW TR
  • [3] ABB, 2010, CAP INT GRIDS
  • [4] ABB, NORNED HVDC CONN NOR
  • [5] ABB, 2005, ENV PROD DECL GIS TY
  • [6] [Anonymous], 2019, EC V 36 DAT CUT OFF
  • [7] [Anonymous], EL EN STOR TECHN OPT
  • [8] Life cycle assessment of transport of electricity via different voltage levels: A case study for Nord-Trondelag county in Norway
    Arvesen, Anders
    Hauan, Ingrid Bjerke
    Bolsoy, Bernhard Mikal
    Hertwich, Edgar G.
    [J]. APPLIED ENERGY, 2015, 157 : 144 - 151
  • [9] Life cycle assessment of an offshore grid interconnecting wind farms and customers across the North Sea
    Arvesen, Anders
    Nes, Rasmus Nikolai
    Huertas-Hernando, Daniel
    Hertwich, Edgar G.
    [J]. INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2014, 19 (04) : 826 - 837
  • [10] Environmental implications of large-scale adoption of wind power: a scenario-based life cycle assessment
    Arvesen, Anders
    Hertwich, Edgar G.
    [J]. ENVIRONMENTAL RESEARCH LETTERS, 2011, 6 (04):