Intracoronary surface changes after Palmaz-Schatz stent implantation: Serial observations with coronary angioscopy

被引:23
作者
Sakatani, H [1 ]
Degawa, T [1 ]
Nakamura, M [1 ]
Yamaguchi, T [1 ]
机构
[1] Toho Univ, Dept Internal Med 3, Meguro Ku, Tokyo 1538515, Japan
关键词
D O I
10.1016/S0002-8703(99)70024-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The objective of this study was to evaluate the appearance of the intraluminal surface after Palmaz-Schatz stent implantation by using coronary angioscopy. Methods and Results Coronary angioscopy was performed immediately after stenting and at 1, 3, and 6 months later in 43 patients with 45 lesions. The presence or absence of red thrombus and/or dissection and the extent of neointimal coverage of the stent struts were analyzed. immediately after stenting, red thrombus and dissection were observed in 9 (41%) and 12 (56%) of 22 lesions, respectively, and these rates decreased with time. Complete coverage of the stent struts by smooth white neointima was observed in 55% of 1 1 lesions at 1 month and in 80% of 21 lesions at 3 months. However, incomplete neointimal coverage was seen in 3 lesions at both 3 and 6 months. Conclusions In human coronary arteries, neointimal coverage of an implanted Palmaz-Schatz stent may take as long as 6 months or more.
引用
收藏
页码:962 / 967
页数:6
相关论文
共 19 条
[1]  
FISCHMAN DL, 1991, CIRCULATION S2, V84, P588
[2]   MULTICENTER INVESTIGATION OF CORONARY STENTING TO TREAT ACUTE OR THREATENED CLOSURE AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - CLINICAL AND ANGIOGRAPHIC OUTCOMES [J].
GEORGE, BS ;
VOORHEES, WD ;
ROUBIN, GS ;
FEARNOT, NE ;
PINKERTON, CA ;
RAIZNER, AE ;
KING, SB ;
HOLMES, DR ;
TOPOL, EJ ;
KEREIAKES, DJ ;
HARTZLER, GO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (01) :135-143
[3]  
HEIJER P, 1993, CATHAT CARDIOVASC DI, V29, P36
[4]  
HEIJER P, 1994, AM HEART J, V128, P656
[5]  
HEIJER P, 1994, J AM COLL CARDIOL, V24, P649
[6]  
KSTRATI A, 1997, CIRCULATION, V96, P462
[7]  
LEON MB, 1996, CIRCULATION S1, V94, P1
[8]  
LEUNG DYM, 1976, SCIENCE, V191, P475
[9]   INTRACORONARY ULTRASOUND OBSERVATIONS DURING STENT IMPLANTATION [J].
NAKAMURA, S ;
COLOMBO, A ;
GAGLIONE, A ;
ALMAGOR, Y ;
GOLDBERG, SL ;
MAIELLO, L ;
FINCI, L ;
TOBIS, JM .
CIRCULATION, 1994, 89 (05) :2026-2034
[10]   EARLY AND LATE RESULTS OF INTRACORONARY ARTERIAL STENTING AFTER CORONARY ANGIOPLASTY IN DOGS [J].
ROUBIN, GS ;
ROBINSON, KA ;
KING, SB ;
GIANTURCO, C ;
BLACK, AJ ;
BROWN, JE ;
SIEGEL, RJ ;
DOUGLAS, JS .
CIRCULATION, 1987, 76 (04) :891-897