Decomposition of 2-chlorophenol in aqueous solution by ultrasound/H2O2 process

被引:54
作者
Lin, JG [1 ]
Chang, CN [1 ]
Wu, JR [1 ]
机构
[1] TUNGHAI UNIV,GRAD INST ENVIRONM SCI,TAICHUNG 40704,TAIWAN
关键词
decomposition; H2O2; pH; pseudo-first-order kinetics; 2-chlorophenol; ultrasound;
D O I
10.1016/0273-1223(96)00288-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Several authors have indicated that ultrasound is effective in oxidizing organic contaminants in water and in wastewater either as the sole means of treatment or in combination with ozonation and UV irradiation. In this work we decomposed 2-chlorophenol (2-cp) in aqueous solution with ultrasound and H2O2. The experiment was conducted with a sonicator (Microson XL-2020) operated at 20 kHz. The double amplitude at the tip of the standard horn (12.7 mm) was adjusted to 0, 72 and 120 mu m, corresponding to power input 0, 125 and 160 W. The initial concentration of aqueous 2-cp solution was 100 mg/l, treated in the system with 0, 100, 200 and 500 mg/l H2O2 individually. The volume of solution was 11 in a mixing flask, and was circulated to the sonication cell at the rate 500 mL/min. Oxygen was continuously purged into the flask. The temperature of solution was kept constant at 25 degrees C and pH was controlled at 3, 5, 7, 9 and 11. The results showed the decomposition of 2-cp was effective at increased amplitude of ultrasound and concentration of H2O2, and smaller pH. At reaction duration 360 min, 2-cp decomposition with 500 mg/l H2O2 was found with 57% improvement over the control, i.e. without H2O2 addition. The pH, controlled below the pKa of 2-cp (8.49 at 25 degrees C), had significantly better decomposition of 2-cp than at greater values. The decomposition rate of 100 mg/l 2-cp was 99% at 120 mu m double amplitude with H2O2 (200 mg/L) and pH 3, after 360 min of reaction. The removal of total organic carbon was found to be only 63%. From analysis of the experimental results, the data on 2-cp decomposition appeared to follow pseudo-first-order reaction kinetics. The squared correlation coefficient, R2, of the model was greater than 0.9 for various pH values. Copyright (C) 1996 IAWQ.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 13 条
[1]   ACOUSTIC CAVITATION PREDICTION [J].
APFEL, RE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 69 (06) :1624-1633
[2]  
CHEN KY, 1994, P 19 WAST TREATM TEC, P14
[3]   CHEMICAL EFFECTS OF ULTRASONICS - HOT SPOT CHEMISTRY [J].
FITZGERALD, ME ;
GRIFFING, V ;
SULLIVAN, J .
JOURNAL OF CHEMICAL PHYSICS, 1956, 25 (05) :926-933
[4]  
GLAZE WH, 1987, ENVIRON SCI TECHNOL, V21, P224, DOI 10.1021/es00157a001
[5]  
GLAZE WH, 1989, J IND ENG CHEM RES, V28, P1537
[6]  
IONESCU SG, 1992, REV ROUM CHIM, V37, P747
[7]  
KATAYAMAHIRAYAM.K, 1992, BIODEGRADATION PHENO
[8]   DECOMPOSITION OF PARATHION IN AQUEOUS-SOLUTION BY ULTRASONIC IRRADIATION [J].
KOTRONAROU, A ;
MILLS, G ;
HOFFMANN, MR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (07) :1460-1462
[9]  
Kotronarou Anatassia, 1992, Environmental Science and Technology, V26, P2420, DOI 10.1021/es00036a013
[10]   CAVITATION-INDUCED DEGRADATION OF PHENOL BY ULTRASOUND [J].
OKOUCHI, S ;
NOJIMA, O ;
ARAI, T .
WATER SCIENCE AND TECHNOLOGY, 1992, 26 (9-11) :2053-2056