An integrated bienzyme glucose oxidase-fructose dehydrogenase-tetrathiafulvalene-3-mercaptopropionic acid-gold electrode for the simultaneous determination of glucose and fructose

被引:33
作者
Campuzano, S [1 ]
Loaiza, SA [1 ]
Pedrero, M [1 ]
de Villena, FJM [1 ]
Pingarrón, JM [1 ]
机构
[1] Univ Complutense Madrid, Fac CC Quim, Dept Quim Anal, E-28040 Madrid, Spain
关键词
glucose; fructose; bienzyme biosensor; self-assembled monolayers; amperometric detection;
D O I
10.1016/j.bioelechem.2003.10.019
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A bienzyme biosensor for the simultaneous determination of glucose and fructose was developed by coimmobilising glucose oxidase (GOD), fructose dehydrogenase (FDH), and the mediator, tetrathiafulvalene (TTF), by cross-linking with glutaraldehyde atop a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM) on a gold disk electrode (AuE). The performance of this bienzyme electrode under batch and flow injection (FI) conditions, as well as an amperometric detection in high-performance liquid chromatography (HPLC), are reported. The order of enzyme immobilisation atop the MPA-SAM affected the biosensor amperometric response in terms of sensitivity, with the immobilisation order GOD, FDH, TTF being selected. Similar analytical characteristics to those obtained with single GOD or FDH SAM-based biosensors for glucose and fructose were achieved with the bienzyme electrode, indicating that no noticeable changes in the biosensor responses to the analytes occurred as a consequence of the coimmobilisation of both enzymes on the same MPA-AuE. The suitability of the bienzyme biosensor for the analysis of real samples under flow injection conditions was tested by determining glucose in two certified serum samples. The simultaneous determination of glucose and fructose in the same sample cannot be performed without a separation step because at the detection potential used (+ 0.10 V), both sugars show amperometric response. Consequently, HPLC with amperometric detection at the TTF-FDH-GOD-MPA-AuE was accomplished. Glucose and fructose were simultaneously determined in honey, cola softdrink, and commercial apple juice, and the results were compared with those obtained by using other reference methods. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 13 条
[1]   A tri-enzyme electrode probe for the sequential determination of fructose and glucose in the same sample [J].
Antiochia, R ;
Palleschi, G .
ANALYTICAL LETTERS, 1997, 30 (04) :683-697
[2]   Carbon paste mediated, amperometric, thin film biosensors for fructose monitoring in honey [J].
Bassi, AS ;
Lee, E ;
Zhu, JX .
FOOD RESEARCH INTERNATIONAL, 1998, 31 (02) :119-127
[3]   New ways of enzymatic two-substrate determinations in flow injection systems [J].
Becker, TM ;
Schmidt, HL .
ANALYTICA CHIMICA ACTA, 2000, 421 (01) :7-18
[4]   An integrated electrochemical fructose biosensor based on tetrathiafulvalene-modified self-assembled monolayers on gold electrodes [J].
Campuzano, S ;
Gaálvez, R ;
Pedrero, M ;
Manuel de Villena, FJ ;
Pingarrón, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (04) :600-607
[5]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[6]   AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON A TETRATHIAFULVALENE-MEDIATED EPOXY-GRAPHITE BIOCOMPOSITE [J].
CESPEDES, F ;
MARTINEZFABREGAS, E ;
ALEGRET, S .
ELECTROANALYSIS, 1994, 6 (09) :759-763
[7]  
HENRY RJ, 1979, QUIMICA CLIN BASES T
[8]   SIMULTANEOUS DETERMINATION OF GLUCOSE, FRUCTOSE, AND SUCROSE IN MIXTURES BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYME REACTORS [J].
MATSUMOTO, K ;
KAMIKADO, H ;
MATSUBARA, H ;
OSAJIMA, Y .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :147-151
[10]   Tetrathiafulvalene as a mediator for the electrocatalytic oxidation of L-ascorbic acid [J].
Murthy, ASN ;
Anita .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :191-193