Analysis of human breath samples with a multi-bed sorption trap and comprehensive two-dimensional gas chromatography (GC x GC)

被引:87
作者
Libardoni, Mark
Stevens, P. T.
Waite, J. Hunter
Sacks, Richard
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Atmospher Ocean & Space Sci, Ann Arbor, MI 48109 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2006年 / 842卷 / 01期
关键词
GC x GC; human breath analysis; instrument design; FID;
D O I
10.1016/j.jchromb.2006.05.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multi-bed sorption trap designed to quantitatively collect volatile organic compounds from large-volume vapor samples and inject them into a gas chromatograph is combined with a comprehensive two-dimensional gas chromatograph (GC x GC) for the analysis of organic compounds in human breath samples. The first-column effluent of the GC x GC is modulated by a single-stage, resistively-heated and air-cooled segment of 0.18-mm i.d. stainless steel column using the same stationary phase as the first column. Cooling gas is provided by a two-stage conventional refrigeration system, and thus no consumables other than carrier gas and electric power are required. The sorption trap uses four discreet beds, three containing different grades of graphitized carbon and one containing a carbon molecular sieve. The ordering of the beds in the trap tube is from the weakest to strongest adsorbent during sample collection. Breath samples are collected in gas sampling bags, and samples are passed through the trap at a flow rate of about 50 cm(3)/min. After sample collection, hydrogen carrier gas flow is initiated in the direction opposite to the sample collection flow, and the metal trap tube is resistively heated to inject a sample plug into the GC x GC. Performance data for the combined GC x GC/sorption-trap instrument is described, and human breath-sample chromatograms are presented. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 40 条
[1]  
Baltussen E, 1998, HRC-J HIGH RES CHROM, V21, P332
[2]   Comprehensive two-dimensional gas chromatography: metrics, potentials, limits [J].
Blumberg, LM .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :29-38
[3]   THERMAL-DESORPTION EFFICIENCIES FOR DIFFERENT ADSORBATE ADSORBENT SYSTEMS TYPICALLY USED IN AIR MONITORING PROGRAMS [J].
CAO, XL ;
HEWITT, CN .
CHEMOSPHERE, 1993, 27 (05) :695-705
[4]   Double-layer Tedlar bags: a means to limit humidity evolution of air samples and to dry humid air samples [J].
Cariou, S ;
Guillot, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (02) :468-474
[5]  
CHEN S, 1970, J LAB CLIN MED, V75, P628
[6]   Decomposition of alpha-pinene and sabinene on solid sorbents, Tenax TA and Carboxen [J].
Coeur, C ;
Jacob, V ;
Denis, I ;
Foster, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 786 (01) :185-187
[7]   A new 'online' method to measure increased exhaled isoprene in end-stage renal failure [J].
Davies, S ;
Spanel, P ;
Smith, D .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (04) :836-839
[8]   Anthropogenic volatile organic compounds in ambient air and natural waters: a review on recent developments of analytical methodology, performance and interpretation of field measurements [J].
Dewulf, J ;
Van Langenhove, H .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :163-177
[9]   Human breath emissions of VOCs [J].
Fenske, JD ;
Paulson, SE .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (05) :594-598
[10]   Application of low-temperature glassy carbon-coated macrofibers for solid-phase microextraction analysis of simulated breath volatiles [J].
Giardina, M ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1604-1614